5.4 ADJUSTING FOR THE CORRECT GAS FLOW
PLEASE CONSIDER THAT GOOD WELDING RESULTS CAN ONLY BE ACHIEVED WITH A CORRECTLY
ADJUSTED GAS FLOW.
In order to configure the correct gas flow, activate the
"Gas valve" in the "Settings" menu (see chapter 5.5). This
opens the gas valve in the welding device. Now set the
flow regulator to the correct flow rate of approx. 2 - 3
litres/min. In doing so, also observe the instructions
provided with the flow regulator. Once the gas volume is
correctly adjusted, close again the "Gas valve" function by
pressing the corresponding button.
5.5 OPERATING LEVEL "SETTINGS"
The "Settings" user level can be used to modify basic settings and launch various test functions.
•
Gas valve:
Pressing the corresponding button
causes the gas valve to be
opened. This function is important
in order to set the correct gas flow on the flow regulator
(see chap. 5.4). Pressing the button again causes the gas
valve to be closed. In addition, any other operation of the
device will automatically quit that function.
•
Filter test:
P
ressing this button causes a
shading of the eye protection filter.
This enables correct function of the eye protection filter to
be checked.
Pressing the button again quits the test.
•
LED light:
P
ressing the button enables the
brightness of the LED lamp on the
welding microscope to be adjusted in 3 steps or to be
switched off.
•
Program memory:
You can activate or deactivate the
saving and calling functions for
programs
that
you
created
yourself here. If this menu is
activated, it appears as an additional user level. The user
levels can be toggled by pressing the rotary controller for
1 second.
•
Expert Menü:
The expert menu can be activated
here. If this menu is active, it
appears as an additional user
level. The user levels can be toggled by pressing the
rotary controller for 1 sec. or longer.
•
Fixation:
Pressing this button activates or
deactivates the operating menu for
fixation welding. If this menu is
activated, it appears as an
additional user level. The user levels can be toggled by
pressing the rotary controller for 1 sec. or permanently.
•
Micro:
The
“micro”
menu can be activated
here. If this menu is active, it
appears as an additional user
level. The user levels can be toggled by pressing the
rotary controller for 1 sec.
•
Welding sequence:
You can press the button to
preselect a "standard" or "short"
basic welding sequence. If you
select "short", a shortened gas pre-
flow time results in a shorter time gap for triggering in a
series of welding points.
•
Language:
Pressing the button with the country
codes enables the system language
for the welding device to
be changed. The system can be toggled between English,
German, Spanish, French, Italian and Russian.
Summary of Contents for PUK U5