© Lampert Werktechnik GmbH
2012
16
9.3
OPTICAL DATA MICROSCOPE
Lens
Ocular
Working distance
Magnification factor
Field of view
1.0
10x
140 mm
10x
20 mm
9.4
TECHNICAL DATA LCD SHUTTER
Light shade
Dark shade
Switching time
UV protection
IR protection
DIN 3
DIN 11
<50ms
>UV 15
>IR 14
9.5 TYPE PLATE
Explanation of pictographs:
Current
Voltage
Protection
type
Hertz
Alternating
current
(AC)
Direct
current
1 ~ 50-60Hz
Mains input
1 phase / AC
/ 50-60Hz
Read
operating
manual
No-load
voltage
Mains
voltage
Voltage at
nominal load
Tungsten
inert gas
welding
Earthing
(earth)
Nominal
welding
current
Power
consumption
under max.
load
Power
consumption
under
nominal load
Cyclic
duration
factor
Single-phase
transformer
10. TROUBLESHOOTING
10.1 WELDING DEVICE
FAULT
CAUSE
REMEDY
1
No welding current
Mains master switch on,
display remains off
Mains cable interrupted
Check mains cable and mains voltage
Device fuse blown
Replace device fuse with identical
fuse (same type and value)
2
No welding current
Mains master switch on
Welding cable connections interrupted Check plugged connections
Poor or zero contact to the workpiece
Establish connection to the workpiece,
fasten contact clamps directly to the
workpiece