L1 Valitse
Mittaukset
Säätökäyrien as
Kellotoiminnat
L1 Ohjaustavat
Automaattiohj.
Jatkuva päivä
Jatkuva yö
Alasajo
Käsiajo mek.
Käsiajo sähk.
Käsiajo sähk.
Ajo: -/+ näppäim
Asento:
Kiinni Auki
39%
The regulator keeps a
nominal temperature on
disregarding the clock
program.
OK
_
+
Press the
button to move cursor to "Operat. modes”. Press
OK.
Each regulating circuit can be controlled with the operating modes
mentioned below. The factory set automatic regulation is a normal
regulating situation in which the clock controlled temperature drops
are also possible.
The selected operating mode always appears on the basic
display on the top line.
Press
the
button to browse operating modes.
The
character indicates which operating mode has been selected.
Move the cursor to the operating mode that you want. Press
Exit with
Changing operating mode:
OK.
ESC.
OPERATING MODES
Manual electr.
Control
Position: 39%
Open
Reduced operat. mode:
Automatic control:
OK
_
+
Continuous reduced
temperature (nighttime
drop) is on regardless
of the clock program.
Temperature drops occur
according to the clock program.
Supply water
Stand-by:
No electricity to actuator.
Only mechanical manual operation of actuator is possible.
Room temperature
Manual operation of actuator mechanically:
Additional information about operating modes in heating regulating circuits H1 and H2:
H1 Select
Heating curve
Settings
Measurements
Info water temp
Operat. modes
Clock functions
H1 Operat.modes
Automatic oper.
Nominal oper.
Reduced oper.
Stand-by
Manual mech.
Manual electr.
Press
Press
ESC
until the display no longer changes.
You are then in the "Selection" display shown in the adjoining picture.
the
button to move from one regulating circuit to the next
(H1, H2, HW).
OPERATING INSTRUCTION:
Press
OK.
H1
Outdoor
°C
SupplyTemp
°C
Selection
Automatic
-15
52
HW Operat.modes
Automatic oper.
Manual mech.
Manual electr.
Operating modes in domestic hot water regulating circuit (HW)
Press
the
button to move to the HW-circuit.
Manual operation of actuator electrically:
OK.
-
+
OK.
Press
Press the
or
button to change the position of the actuator.
The direction the actuator is being run can be seen from the display.
The position's %-reading indicates the actuator`s position if a voltage
controlled 0...10V or 2...10V actuator (0% = closed, 100% = open) is
being used. Confirm the actuator position by pressing
The valve can also be connected so that 100% is closed.
H1
OPERA
T.MODE
Automatic/
Nominal
oper
./
Reduced
oper
./
Manual
electr
.
open=
%/
Manual
electr
.
close=
%/
Valve
flushing/
H1
OPERA
T.MODE
*
000
000
Nominal operat. mode:
Free supply water
temperature drop down
to the freeze protect limit
(stand-by function).
12
KEYWORDS:
H1 Operat.modes
H2 Operat.modes
DHW Settings