background image

L A N C A S T

®

Installation & User Guide

Models: 2111-12-01 / 2111-12-02 / 2111-13-01 / 2111-13-02 / 2111-15-01

2111-15-02 / 2111-16-01 / 2111-16-02 / 2111-18-01 / 2111-18-02

L

ANCAST

®

“twister”

™  

2111

10M

BPS

 M

EDIA 

C

ONVERTER

TX

RX

MM

LK

LK

AT

AT

PWR

10BASE-FL

10BASE-T

“twister”   

2111

®

TX

RX

SM

LK

LK

AT

AT

PWR

10BASE-FL

10BASE-T

“twister”   

2111

®

COL

LK

PWR

10BASE-2

10BASE-T

“twister”   

2111

®

AT

TX

RX

SM

LK

LK

AT

AT

PWR

10BASE-FL

10BASE-T

“twister”   

2111

®

Summary of Contents for 2111-15-012111-15-02 / 2111-16-01 / 2111-16-02 / 2111-18-01 / 2111-18-02

Page 1: ...5 02 2111 16 01 2111 16 02 2111 18 01 2111 18 02 LANCAST twister 2111 10MBPS MEDIA CONVERTER TX RX MM LK LK AT AT PWR 10BASE FL 10BASE T twister 2111 TX RX SM LK LK AT AT PWR 10BASE FL 10BASE T twister 2111 COL LK PWR 10BASE 2 10BASE T twister 2111 AT TX RX SM LK LK AT AT PWR 10BASE FL 10BASE T twister 2111 ...

Page 2: ...__ TX to FX singlemode SC 40km universal AC 2131 1A 01 __ TX to SX multimode SC universal AC 2131 1B 01 ___ TX to SX multimode ST universal AC 2131 34 01 ___ FX multimode SC to FX singlemode SC universal AC 2131 36 01 ___ FX multimode SC to FX singlemode ST universal AC 2131 54 01 ___ FX multimode ST to FX singlemode SC universal AC 2131 56 01 ___ FX multimode ST to FX singlemode ST universal AC 1...

Page 3: ...uide 16 System LEDs 16 Link Loss Carry Forward LLCF 17 Topology Solutions 18 Technical Specifications 20 Product Safety EMC and Compliance Statements 22 Warranty and Servicing 23 Lancast and the Lancast logo are registered trademarks and twister is a trademark of Lancast Inc All others are trademarks of their respective owners The information contained in this document is assumed to be correct and...

Page 4: ...ing a mixed media environment As LANs grow and evolve this technology provides an ideal solution for building effective migration strategies These IEEE 802 3 compliant media converters are compatible with Ethernet devices from other leading network technology providers This increases the flexibility of your network configuration by ensuring reliable data transmission in multi vendor as well as mix...

Page 5: ...ble disable switch is included to provide an easy means for troubleshooting a remote network connection Refer to the section of this guide titled Link Loss Carry Forward for more information All twisted pair ports are equipped with an MDI II to MDI X switch eliminating the need for crossover cables Auto polarity support on all twisted pair ports Whether you are updating or expanding your existing ...

Page 6: ...6 ...

Page 7: ...opriate location The twister 2111 media converter is intended for use in either office or industrial environments The unit must be located within six 6 feet of the AC power source being used and placed as far away as possible from electrical noise generating equipment such as copiers electrostatic printers and other motorized equipment If exposed twisted pair wiring is used nearby the wiring shoul...

Page 8: ...d the fiber optic ports as well as the twisted pair ports on the twister media converter do not transmit a link signal until they receive a link signal from the opposite port Refer to the page titled Link Loss Carry Forward in the User Guide section of this manual for more detailed information The unit is shipped with the LLCF disabled To re set the LLCF simply slide the switch to the appropriate ...

Page 9: ...rough or parallel connection the cross symbol X indicates a crossover connection These symbols are clearly marked on the bottom of the unit Using a pointed object simply slide the switch in the direction of the appropriate symbol Use the following table as a guide TX RX SM PWR 10BASE FL 10BASE T twister 2111 LK AT LK AT MDI II MDI X Switch TX RX SM LK LK AT AT PWR 10BASE FL 10BASE T twister 2111 A...

Page 10: ...ister 2111 provides one shielded RJ 45 connector for Category 3 4 or 5 twisted pair segments and supports a maximum link length of 100 meters NOTE Be sure you have set the MDI II to MDI X switch located on the bottom of the unit to the proper configuration Refer back to STEP 3 if necessary Once power is applied to the unit correct connectivity can be verified via the LK link LED 4 TX RX SM LK LK A...

Page 11: ...11 15 01 02 provide one set of FL multimode ST connectors and suppport a maximum segment length of up to 2km for remote links the 2111 16 01 02 provide one set of FL singlemode ST connectors and support a maximum segment length of up to 15km for remote links the 2111 18 01 02 provide one set of FL multimode SMA connectors and suppport a maximum segment length of up to 2km for remote links TX RX SM...

Page 12: ...ster unit Once power is applied to the unit correct connectivity can be verified via the LK Link LED BNC Connection 2111 12 The twister 2111 12 attaches to thinnet coaxial cable via a standard BNC connector and supports a maximum segment length of 185 meters The twister 2111 12 is shipped from the factory with the termination disabled Use the unit in a daisy chain configuration or use a T connecto...

Page 13: ... the two terminators on each segment must be grounded Refer to the illustration below Ground Wire Workstation Workstation Workstation Workstation Workstation Workstation Workstation Wall Outlet Grounded BNC Terminator BNC Terminator BNC T Connector Repeater twister SEGMENT 1 0 5 meters min 185 meters max Wall Outlet Ground Wire Grounded BNC Terminator SEGMENT 2 0 5 meters min 185 meters max Workst...

Page 14: ...e Refer to page 5 for a listing of models using the 90 250V universal desktop power supply and the 115V domestic desktop power supply When making power connections it is recommended that the DC power cord be connected to the DC input jack located on the back of the twister media converter before making the AC connection to the outlet Be sure to seat the power cord into the strain relief clip to en...

Page 15: ...o the twister power supply module must have a female plug that fits this type of AC receptacle AC 115V North American use a UL listed and CSA certified cord set consisting of a minimum 18 AWG type SVT or SJT three conductor cord a maximum of 15 feet in length and a parallel blade grounding type attachment plug rated 15A 125V AC 230V USA use a UL listed cord set consisting of a minimum No 18 AWG ty...

Page 16: ...roubleshooting and overall network diagnosis and management LEDs indicate the following PWR power the unit is ON and functioning in normal operation mode LK link twisted pair and fiber optic ports satisfactory link status on the respective port AT activity the port is receiving data COL collision detection of a collision condition and subsequent JAM packets generated on both segments Once power is...

Page 17: ...CF is enabled and two twister media converters are connected via a fiber cable with nothing else connected to them the Link LED does not illuminate When a valid link is established at the twisted pair port a complete connection is accomplished The diagram below shows a typical network configuration using a twister media converter for remote connectivity If the fiber connection breaks or the remote...

Page 18: ...18 User Guide Topology Solutions F O Links Twisted pair Links Switch 2km multimode F O 15km singlemode F O Servers twister 2111 twister 2111 ...

Page 19: ... twister 2111 Media Converter 19 Enterprise Switch Switch 2km multimode F O twister 2111 twister 2111 Enterprise ...

Page 20: ..._______________ 32 5 dBm peak minimum Output Power _________________ 21 8 dBm to 16 8 dBm 50 125 µm ______________________ 19 dBm to 14 dBm 62 5 125 µm Supported Link Length _______________________ up to 2km full duplex Cable Type ______________________ 50 125 62 5 125 100 140 µm F O Singlemode Fiber Optic Interface Connector ________________________________________________ ST RX Input Sensitivity...

Page 21: ..._____________________ 0 55 C Storage Temperature ________________________________ 25 70 C Relative Humidity _____________________ 5 95 non condensing Physical Case _____________________Fully enclosed metal construction Dimensions ______________________________5 0 L x 3 5 W x 1 6 H Weight __________________________ 3 lbs including power supply Regulatory Compliance _________________________________...

Page 22: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his ow...

Page 23: ...o return a defective product for warranty coverage contact Lancast Customer Service for a return materials authorization RMA number Send the defective product postage and insurance prepaid to the address provided to you by the Lancast Technical Support Representative Failure to properly protect the product during shipping may void this warranty The Lancast RMA number must be clearly on the outside...

Page 24: ...L A N C A S T 12 Murphy Drive Nashua NH 03062 USA tel 603 880 1833 fax 603 594 2887 www lancast com 5660 211112 001 A 6 99 ...

Reviews: