background image

9

SPECIFICATIONS

ONE E3-M Name 

and Part Number

Size and  

Micron Rating

Rated Capacity  

and Flow Rate

Peak Flow and % Reduction 

of Lead and PFOA/PFOS

Chlorine/chloramine Taste and  

Odor Reduction Capacity

*

Pressure  

Drop Spec

ONE E3-M System and PIONEER Pb Filter

ONE E3-M System 

7-CTFS-NSF

8" x 40" / 

0.5 Microns

Lead Reduction and PFOA/PFOS

100,000 gallons @ 4.51 GPM 

(378,541 Liters @ 17.1 lpm) 

@ 99.62% lead reduction 

@ 97.9% PFOA/PFOS reduction

8 GPM 

(30.2 lpm)

 

@ 99.62% lead reduction  

@ 97.9% PFOA/PFOS reduction

>88,000 gallons at 8 GPM

*

 

(333,116 Liters @ 30.2 lpm)

>300,000 gallons @ 15 GPM 

(1,135,533 

Liters @ 56.8 lpm) 

with greater than 90% 

reduction, estimated capacity using 2 

ppm of free chlorine

>150,000 gallons @ 8 GPM (567,812 

Liters @ 30.3 lpm) with greater than 

85% reduction, estimated using 3 

ppm of chloramine

9 psid @ 

4.51 GPM

Replacement Cartridge Filters Are Listed as PIONEER Pb—0.5 Micron High Capacity Carbon Block   //  

PART NUMBER: CT-NSF-CB

If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or galvanized metal, the plastic components of the system 
will interrupt the continuity of the plumbing system. As a result any errant electricity from improperly grounded appliances downstream or potential 
galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing. Some homes may have been built in accordance 
with building codes, which actually encouraged the grounding of electrical appliances through the plumbing system. Consequently, the installation of a 
bypass consisting of the same material as the existing plumbing, or a grounded “jumper wire” bridging the equipment and reestablishing the contiguous 
conductive nature of the plumbing system must be installed prior to your systems use.

DO NOT USE

 extra lubricants, unapproved sealants and tools to tighten hand tightened only parts. Use of tools other than hand tighten only parts 

voids warranty. Testing was performed under standard laboratory conditions; actual performance may vary. Flush the system and change the filter as 
suggested. The contaminants or other substances removed or reduced by this water filter are not necessarily in all users’ water.

WARNINGS

*Claims are not performance tested by IAPMO or NSF. Performance claims are based on independent laboratory and manufacturer’s internal test data. Actual performance is dependent on influent  
  water quality, flow rates, system design and application. Results may vary.

This system conforms to NSF/ANSI 53 for the specific performance claims verified and substantiated by test data. Performance claims are based on 
independent lab results and manufacturer’s internal test data

*

. Actual performance is dependent on influent water quality, flow rates, system design and 

applications. Your results may vary. Performance claims are based on a complete system, including a filter, housing, and connection to a pressurized 
water source. This filter must be operated according to the system’s specifications in order to deliver the claimed performance. It is essential to follow 
operational, maintenance, and filter replacement requirements, as directed for each application, for this filter and system to perform correctly. Read the 
Manufacturer’s Performance Data Sheet accompanying the system and change the filter as suggested. The contaminants or other substances removed 
or reduced by this water filter are not necessarily in all users’ water.

PERFORMANCE

Minimum Operating Temperature:

 34 °F / 1 °C

Maximum Operating Temperature:

 120 °F / 50 °C

Minimum Operating Pressure:

 20 psig / 1.38 bar

Maximum Operating Pressure: 

125 psig / 8.6 bar

Electrical Requirements:

 Grounded and unswitched 115 V outlet and 3-AAA Batteries

Filter Replacement Operating Instructions:

 New cartridges must be flushed for a minimum of 10 minutes prior to use. System and 

installation to comply with state and local laws and regulations. 

Do not

 use with water that is microbiologically unsafe or unknown quality 

without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that  
may contain filterable cysts. Manufactured from NSF/ANSI standard 61 and California Prop 65 Compliant certified coconut shell carbon  
and raw materials.

OTHER SPECIFICATIONS

Substance

Influent Challenge Concentration (MG/L)

Maximum Permissible Product Water Concentration (MG/L)

NSF/ANSI Standard

Lead

0.15 +/- 10%

0.005

53

Cyst

Minimum 50,000/L

99.95%

53

PFOA/PFOS

1.5 +/- 10%

0.07

53

Summary of Contents for ONE E3-M

Page 1: ...OLUTIONS This manual should be kept for future reference If you have any questions regarding your water filter contact your local dealer OEM or the manufacturer at the following Lancaster Water Group...

Page 2: ...f your home to relieve water pressure by draining it from lines Installing Ground To maintain an electrical ground in metal plumbing of a home s cold water piping such as a copper plumbing system inst...

Page 3: ...METERASSY 5 Meter Spacer Assembly CT METERSPACER 6 Bypass Manifold CT IOHMBK BYPASSMANIFOLD GR 7 1 MNPT Straight Connector CT 1MNPTSTRAIGHT 8 1 MNPT 90 Degree Elbow Connector CT 1MNPTELBOW 9 3 8 PEX D...

Page 4: ...Teflon tape Install thread 9 Drain Valve Assembly into 3 HAND TIGHTEN ONLY STEP 1C Connect 4 to 3 Flow Meter Assembly should be placed on the Outlet Side left side at the bottom of the tank Connect 5...

Page 5: ...pull the cap out of the top of the tank STEP 4A Place the top cap back into its original location STEP 4B Reattach the snap ring then pull up on the cap to lock in the O rings STEP 4 REATTACH THE TOP...

Page 6: ...should be reinstalled into the bottom connection for proper installation of filter 8 Open the fitting and shut off and then flush out the bottom of the system 9 Look down into the tank assembly and l...

Page 7: ...lace the filter in their E3 M system by following a few simple steps LED REPLACEMENT NOTIFICATIONS EASY TO UNDERSTAND LED REPLACEMENT NOTIFICATIONS EASY FILTER REPLACEMENTS WITH NO TOOLS REQUIRED 1 PR...

Page 8: ...u have questions or concerns please contact Lancaster Water Group at 1 800 442 0786 90 Degree Elbow Connectors 2 Umbrella Cap Filter Cap Filter Housing Bypass Manifold In Out Head w Filter Adapter 2 5...

Page 9: ...ilter are not necessarily in all users water WARNINGS Claims are not performance tested by IAPMO or NSF Performance claims are based on independent laboratory and manufacturer s internal test data Act...

Page 10: ...wait 2 seconds and repeat Refer to the figures below for an example FIGURE 1 To change the maximum gallons setting press and hold the button for 1 second LED 1 should turn solid green LED 2 should tu...

Page 11: ...11...

Page 12: ...or translated into another language without the prior written consent of LANCASTER WATER TREATMENT Copyright 2022 LANCASTER WATER TREATMENT All rights reserved POWERED BY Where Innovation Flows This...

Reviews: