9
SPECIFICATIONS
ONE E3-M Name
and Part Number
Size and
Micron Rating
Rated Capacity
and Flow Rate
Peak Flow and % Reduction
of Lead and PFOA/PFOS
Chlorine/chloramine Taste and
Odor Reduction Capacity
*
Pressure
Drop Spec
ONE E3-M System and PIONEER Pb Filter
ONE E3-M System
7-CTFS-NSF
8" x 40" /
0.5 Microns
Lead Reduction and PFOA/PFOS
100,000 gallons @ 4.51 GPM
(378,541 Liters @ 17.1 lpm)
@ 99.62% lead reduction
@ 97.9% PFOA/PFOS reduction
8 GPM
(30.2 lpm)
@ 99.62% lead reduction
@ 97.9% PFOA/PFOS reduction
>88,000 gallons at 8 GPM
*
(333,116 Liters @ 30.2 lpm)
>300,000 gallons @ 15 GPM
(1,135,533
Liters @ 56.8 lpm)
with greater than 90%
reduction, estimated capacity using 2
ppm of free chlorine
>150,000 gallons @ 8 GPM (567,812
Liters @ 30.3 lpm) with greater than
85% reduction, estimated using 3
ppm of chloramine
9 psid @
4.51 GPM
Replacement Cartridge Filters Are Listed as PIONEER Pb—0.5 Micron High Capacity Carbon Block //
PART NUMBER: CT-NSF-CB
If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or galvanized metal, the plastic components of the system
will interrupt the continuity of the plumbing system. As a result any errant electricity from improperly grounded appliances downstream or potential
galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing. Some homes may have been built in accordance
with building codes, which actually encouraged the grounding of electrical appliances through the plumbing system. Consequently, the installation of a
bypass consisting of the same material as the existing plumbing, or a grounded “jumper wire” bridging the equipment and reestablishing the contiguous
conductive nature of the plumbing system must be installed prior to your systems use.
DO NOT USE
extra lubricants, unapproved sealants and tools to tighten hand tightened only parts. Use of tools other than hand tighten only parts
voids warranty. Testing was performed under standard laboratory conditions; actual performance may vary. Flush the system and change the filter as
suggested. The contaminants or other substances removed or reduced by this water filter are not necessarily in all users’ water.
WARNINGS
*Claims are not performance tested by IAPMO or NSF. Performance claims are based on independent laboratory and manufacturer’s internal test data. Actual performance is dependent on influent
water quality, flow rates, system design and application. Results may vary.
This system conforms to NSF/ANSI 53 for the specific performance claims verified and substantiated by test data. Performance claims are based on
independent lab results and manufacturer’s internal test data
*
. Actual performance is dependent on influent water quality, flow rates, system design and
applications. Your results may vary. Performance claims are based on a complete system, including a filter, housing, and connection to a pressurized
water source. This filter must be operated according to the system’s specifications in order to deliver the claimed performance. It is essential to follow
operational, maintenance, and filter replacement requirements, as directed for each application, for this filter and system to perform correctly. Read the
Manufacturer’s Performance Data Sheet accompanying the system and change the filter as suggested. The contaminants or other substances removed
or reduced by this water filter are not necessarily in all users’ water.
PERFORMANCE
Minimum Operating Temperature:
34 °F / 1 °C
Maximum Operating Temperature:
120 °F / 50 °C
Minimum Operating Pressure:
20 psig / 1.38 bar
Maximum Operating Pressure:
125 psig / 8.6 bar
Electrical Requirements:
Grounded and unswitched 115 V outlet and 3-AAA Batteries
Filter Replacement Operating Instructions:
New cartridges must be flushed for a minimum of 10 minutes prior to use. System and
installation to comply with state and local laws and regulations.
Do not
use with water that is microbiologically unsafe or unknown quality
without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that
may contain filterable cysts. Manufactured from NSF/ANSI standard 61 and California Prop 65 Compliant certified coconut shell carbon
and raw materials.
OTHER SPECIFICATIONS
Substance
Influent Challenge Concentration (MG/L)
Maximum Permissible Product Water Concentration (MG/L)
NSF/ANSI Standard
Lead
0.15 +/- 10%
0.005
53
Cyst
Minimum 50,000/L
99.95%
53
PFOA/PFOS
1.5 +/- 10%
0.07
53