Problem

Possible Cause

Solution

13. Water running to drain

a. Power outage during regeneration

a. Upon power being restored control will 

finish the remaining regeneration time. 

Reset time of day. 

b. Damaged seal/ stack assembly

b. Replace seal/ stack assembly

c. Piston assembly failure

c. Replace piston assembly

d. Drive cap assembly not tightened in 

properly

d. Re-tighten the drive cap assembly

14. Err – 101 = Control unable to sense motor 

movement

a. Motor not inserted full to engage pinion, 

motor wires broken or disconnected

a. Disconnect power, make sure motor is 

fully engaged, check for broken wires, 

make sure two pin connector on motor 

is connected to the two pin connection 

on the PC Board labeled MOTOR. Press 

NEXT and REGEN buttons for 3 seconds 

to resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

b. PC Board not properly snapped into drive 

bracket

b. Properly snap PC Board into drive bracket 

and then Press NEXT and REGEN 

buttons for 3 seconds to resynchronize 

software with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

c. Missing reduction gears

c. Replace missing gears

15. Err – 102 = Control valve motor ran too 

short and was unable to find the next cycle 

position and stalled

a. Foreign material is lodged in control valve

a. Open up control valve and pull out piston 

assembly and seal/ stack assembly for 

inspection. Press NEXT and REGEN 

buttons for 3 seconds to resynchronize 

software with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

b. Mechanical binding

b. Check piston and seal/ stack assembly, 

check reduction gears, check drive 

bracket and main drive gear interface. 

Press NEXT and REGEN buttons for 3 

seconds to resynchronize software with 

piston position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

c. Main drive gear too tight

c. Loosen main drive gear. Press NEXT 

and REGEN buttons for 3 seconds 

to resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

d. Improper voltage being delivered to PC 

Board

d. Verify that proper voltage is being supplied. 

Press NEXT and REGEN buttons for 3 

seconds to resynchronize software with 

piston position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

Summary of Contents for IRONSOFT X- FACTOR Series

Page 1: ...rs of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes pl...

Page 2: ...for each ppm iron for total compensated hardness Use the total compensated hardness number for hardness setting on page 8 Total Grains of Compensated Hardness per Day INSTALLATION DATE SERIAL NUMBER I...

Page 3: ...UALITY If sand or sediment is present in the water supply a sediment filter should be installed ahead of the water softener Your water softener has been designed to adequately reduce compensated hardn...

Page 4: ...s are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o r...

Page 5: ...ical plumbing should be done in accordance to all local codes INSTALLATION INSTRUCTIONS 5 The drain connection may be made using either 5 8 polytube see below or a 3 4 female adapter The polytube inse...

Page 6: ...DF XCHANGE w w w docu track c o m C l i c k t o b u y N O W PDF XCHANGE w w w docu track c o m 6 The brine refill flow control assembly is installed in an easy to access refill elbow located on top of...

Page 7: ...salt level should be checked every couple of weeks to determine salt usage Keeping the brine tank salt level at least 1 2 full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine blea...

Page 8: ...the total compensated hardness number from Page 2 Use the or buttons to set the hardness number The default is 20 with value ranges from 1 to 150 in 1 grain increments Press NEXT to go to step 3 Press...

Page 9: ...rn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward...

Page 10: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Page 11: ...Pipe Connector Assy for Model 7 FESLX 60 1 5 A4102 24V Replacement media for 7 FESLX 24 1 A4102 32V Replacement media for 7 FESLX 32 1 A4102 45V Replacement media for 7 FESLX 45 1 A4102 60V Replacemen...

Page 12: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Page 13: ...etailed service instructions 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back...

Page 14: ...RITICAL OR HEALTH EFFECT APPLICATIONS The nut and caps are designed to be unscrewed or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the...

Page 15: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Page 16: ...tailed operation and service instructions Order No V3007 01 Description Fitting 1 PVC Solvent 90 Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3...

Page 17: ...Split Ring 2 3 V3105 O Ring 215 2 4 V3628 Ftg 3 4 Brass Shark Bite 2 1 1 4 NPT 1 BSPT 1 NPT 3 2 1 4 1 1 4 NPT 1 BSPT 1 NPT 1 3 2 4 CHANGE CHANGE R MAT LTR DATE BY LTR DATE TITLE DATE SCALE PART REV DW...

Page 18: ...PHONE NO 1 608 846 3010 C C Water Specialist 35 Water Softerner Cabinet CONFIG DWG R DWG CHANGE 1 OF 1 X XX X Units Inch Water Specialist CWS 18 Cabinet The Water Specialist CWS 18 C accepts 18 tall m...

Page 19: ...esistance is felt before latching then notches are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the d...

Page 20: ...n the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible through the drain port Exc...

Page 21: ...not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the injector Push the plug s and or injectors firmly in place re...

Page 22: ...ace meter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be deplete...

Page 23: ...leaking fixtures that may be exhausting capacity or system is undersized 10 Residual regenerant being delivered to service a Low water pressure a Check incoming water pressure water pressure must rem...

Page 24: ...supply from PC Board for 5 seconds and then reconnect c Missing reduction gears c Replace missing gears 15 Err 102 Control valve motor ran too short and was unable to find the next cycle position and...

Page 25: ...s NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting...

Page 26: ...PAGE 26 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 5 17...

Reviews: