Setting System ID Switches
The System ID switches on each unit allow the system to distinguish one unit from
another. Cobranet bundle numbers and Ethernet IP addresses are automatically
determined based on the System ID Switches.
The System ID switches are two-digit rotary switches on the rear panel of the ADX-
120 and on the front panel of the ADX-140. The ADX-2400 also has System ID
switches, which are behind the removeable front panel, on the PCB sub-panel.
The range for the switches is from 01 through 99 (00 is not a valid ID). No two
devices may have the same ID number.
Compatibility:
ADX-2400Ds with version 5.1 or later firmware may be used with
earlier ADX-120s or ADX-140s by turning on Dipswitch section 5 on the 2400, and
using IDs for all devices with the first (tens) digit = 0. This is provided as an
emergency or interim operating mode. All devices should be upgraded to version
5.x as soon as practical.
The System ID settings for the ADX-120/140 units become the reference for the
physical unit, and will be used in assigning those units to be A, B, C, and D
designations in the ADX-2400 menus (see next page).