background image

-10-

EN

Troubleshooting: AR 3 Pro

Adjustable Telescopic Lance

Problem

Possible causes

Solutions

No powder 

coming out 

of the flexible 

nozzle.

Check if the flexible nozzle tip cap is 

removed.

If the flexible nozzle is 

damaged, please order:

 

Reference: ARP-03 

Flexible Nozzle Kit - 

Standard tube size 

(8 mm Diameter x 35 cm)

Check that the flexible nozzle isn’t 

damaged or kinked. 

Ensure powder chamber is securely 

screwed onto the lance and the caps 

of the powder chamber and flexible 

nozzle are tight. 

Check that the 1L stainless steel tank 

is pressurised to 3 bar / 44 psi.

Check powder is not damp as this can 

cause blockages.

No pressure 

in the 1L 

stainless steel 

tank.

Check if the front trigger outlet valve is 

screwed onto the tank securely. 

If the front trigger outlet 

valve is damaged, 

please order:

Reference: ARP-07

6 mm Compression push fit 

outlet valve

Check if the inflator valve inner core is 

not leaking air. If air leakage is audible 

the inflator valve inner core needs 

tightened. (Use a standard bike valve 

core remover tool to tighten).

If the tank is still leaking air, 

then please order:

 

Reference: ARP-06 

Inflator valve inner core (Inc 

fitting tool)

Check if the trigger head is screwed 

onto the tank securely. 

Check if the inflator valve is securely 

tightened.

Powder falling 

back down 

inside of the 

lance.

Check if the powder chamber’s 

internal non-return valve located at the 

bottom is damaged. To do this hold 

the filled powder chamber upright and 

over a container, gently shake the 

chamber from side to side (ensure the 

powder chamber top cap is in place). 

If the internal non-return valve is 

damaged, powder will fallout from the 

bottom of the chamber.

If the powder chamber’s 

internal non-return valve 

is damaged, then please 

order:

Reference: ARP-02 

Powder chamber internal 

non-return valve (supplied 

with special fitting tool)

Summary of Contents for AR 3 Pro

Page 1: ...AR 3 Operating Manual AR 3 Pro Adjustable Telescopic Lance for Powder Application READ MANUAL BEFORE USE Art Nr AR3 PRO Pro...

Page 2: ...3 Pro Contents List 3 Safety Information 4 Assembly Instructions 5 6 Extending and using the lance 7 Pressure tank assembly and operation 8 Product Care Advice 9 Maintenance Instructions 9 Troubleshoo...

Page 3: ...tity A PVC Protective Carry Tube 1 B Flexible Nozzle 8 mm Diameter x 35 cm 1 C Powder Chamber 1 D 5g Powder Scoop 1 E Lance Lab AR 3 Pro Lance 1 F 1L Stainless Steel Pressure Tank 1 G End Cap 1 H Rubb...

Page 4: ...afety Regulations 1 1 Please read the instruction manual carefully before operating this equipment for the first time 1 2 Please observe the safety and warning regulations 1 3 Failure to observe these...

Page 5: ...removing straps by pulling gently 4 Now unscrew the caps from the top of the powder chamber and the flexible nozzle 5 Use the powder scoop provided to fill the powder chamber Please note powder is no...

Page 6: ...e top of the lance Do not over tighten 10 Bend the flexible nozzle to the required shape and then remove the yellow tip cap To avoid damage do not bend the flexible nozzle sharply 7 Screw on the powde...

Page 7: ...n ensuring the lance remains in the upright position 1 Extend and twist to lock each section Do not pull sections out too forcefully as joints can be over extended Birchmeier Spr htechnik AG Im Stette...

Page 8: ...st Press the trigger on top of the 1L tank Do not hold down press trigger in short bursts 5 2 Once the treatment is finished hold the lance vertically and collapse down each section at a time Once ful...

Page 9: ...product should be cleaned with a soft dry cloth only Do not use volatile substances or cleaning products as these can cause damage Maintenance Instructions AR 3 Pro Adjustable Telescopic Lance Replaci...

Page 10: ...mm Compression push fit outlet valve Check if the inflator valve inner core is not leaking air If air leakage is audible the inflator valve inner core needs tightened Use a standard bike valve core r...

Page 11: ...Tank ARP 06 Inflator valve inner core Inc fitting tool ARP 07 6 mm Compression rush fit outlet valve ARP 08 Red powder chamber cap and yellow flexible nozzle tip cap 2 pcs ARP3 01 AR 3 Pro Replacemen...

Page 12: ...Calculated using Ficam D powder by Bayer plc therefore other insecticidal powders may vary Storage Supplied with 1 25 m PVC Protective Carry tube Weight Assembled lance weight approximately 0 35 Kg 1L...

Reviews: