11.2 Automatic radiant power distribution
The maximum applicable power is distributed among the active radiant elements,
the last power level
set takes priority over the previous settings on the other radiant elements.
Power is distributed automatically among the two radiant elements on the left (A) and the two on
the right (B).
A
B
RADIANT ELEMENT
1
Ø 180
2
Ø 145
3
Ø 210
POWER (W)
1850
1400
2300
POWER WITH BOOSTER FUNCTION (W)
(ref. section “
11.6.3”)
3000
2200
3700
TOTAL MAXIMUM POSSIBLE POWER (W)
3700
3700
Power is distributed automatically among the three radiant elements on the left (A) and the two
on the right (B).
A
B
RADIANT ELEMENT
1
Ø 145
2
Ø 180
3
Ø 260
2
Ø 180
4
Ø 210
POWER (W)
1400
1600
2400
1600
2300
POWER WITH BOOSTER FUNCTION (W)
(ref. section “
11.6.3”)
1800
3000
3200
3000
3200
TOTAL MAXIMUM POSSIBLE POWER (W)
3700
3700