Programming Portion Size – Top Off
•
Fill any cup with the appropriate amount of ice and place
underneath the nozzle.
•
To enter programming mode, touch the small and extra-large
sizes at the same time.
•
To set the portions, touch the corresponding portion size button
until the desired liquid level is obtained.
•
NOTE: There is a timeout feature that will exit programming mode
after 25.5 seconds of continuous pouring or 25.5 seconds of
inactivity. If timeout occurs, all data will be retained; however, you
must re-enter programming mode to set any remaining sizes.
•
To set the top off portion, let foam settle and touch the same
portion button again until the cup is full.
•
To exit programming mode, touch the pour/cancel button.
4. Dispenser Operation
4.1 Lever
Fill cup with appropriate amount of ice and place under nozzle.
Press cup against level to dispense beverage.
Remove cup to stop.
4.2 Push Button
Fill cup with appropriate amount of ice and place under nozzle.
Press and hold the button on the front panel to dispense beverage.
Release button to stop.
4.3 Portion control
Fill cup with appropriate amount of ice and place under nozzle.
Press the required portion size button to begin dispensing the beverage.
1. The required portion of beverage will pour.
2. Press the Pour/Cancel to stop pour prior to complete dispense.
Press and hold the pour/cancel button, beverage will continue to pour until the button is
released.