Bullet Tower
24VAC / 50Hz
www.lancerbeverage.com
Page 9 of 34
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000028
Images are for illustration purposes only as product may vary.
No 061-2 - 17 December 2019
3.8 Commissioning
•
Turn on the remote chiller and ensure it is operating as per
manufacturer’s instructions.
•
Turn on the tower supply transformer.
•
Ensure the chiller has made an ice-bank.
•
The drink temperature should be no higher than 4.4°C (40°F)
when the brix ratio is set.
•
Check the system for leaks.
•
Ensure the mounting block soda and syrup stems are in the
OPEN position.
•
Be sure the shut-off stems are fully turned to the desired
position or the flow will be restricted.
•
Actuate each dispensing valve to bleed air from the system
until a smooth flow is obtained.
Adjusting Soda/Water Flow
The remote cooling system should have been running for at least two hours before attempting
to brix the valve. If a remote chiller is use, ensure the chiller has made an icebank. The drink
temperature should be no higher than 4.4°C (40°F) when the brix is set.
•
Slide up I.D. panel until flow control adjustments are exposed (see
Figure 1)
•
Remove nozzle by twisting counter clockwise and pulling down.
•
Remove diffuser by pulling down.
•
Install Lancer syrup separator (yellow) (PN 54-0031 for 3Oz valves)
or Lancer syrup separator (smoke) (PN 54-0201 for 4.5Oz valves)
in place of the nozzle.
•
Activate dispensing valve to fill separator syrup tube.
•
Hold a Lancer brix cup under the syrup separator.
•
Operate the valve for 4 seconds.
•
For LEV PC valves touch the medium and large cup size at the same
time (for 1 second, light blinks) to dispense soda/water and syrup into
the cup for 4 seconds.
•
For Versapour PC valves touch the small and large cup size at the same
time for 1 second, to dispense soda/water and syrup into the cup for 5
seconds.
•
Divide number of ml (oz.) of soda/water in the cup by 4 (5 for Versapour
PC valves) to determine water flow rate per second.
•
To obtain the required flow, use a screwdriver to
adjust the soda/water flow control. Adjust
clockwise to increase the soda/water flow and anti-
clockwise to decrease the soda/water flow.