3.6
WEEKLY ADJUSTING OF WATER TO SYRUP (RATIO) BRIX (
LFCV
®
)
A. Hold the Lancer brix cup under the syrup separator and activate valve. Check brix.
B. To obtain the proper brix, use screwdriver to adjust syrup flow control.
C. Once proper ratio is obtained repeat to verify.
D. Remove syrup separator (PN 54-0362 installed in Section 3.5.G above).
E. Install nozzle.
F.
Repeat process for each valve.
G. Once all of the valves have been brixed, restore switches panel and light panel to their original
positions.
3.7
CARBONATOR PUMP MODIFICATIONS
NOTE
The electric, positive displacement, rotary vane pump with replaceable (250 PSI) bypass, is
maintenance-free. Only trained personnel should service pump. Additionally, it is not
recommended that the pump be used with hard water.
A. Servicing
1.
Turn unit off.
2.
Remove drip tray and splash plate.
3.
Turn the CO
2
off, activate the relief valve.
4.
Once the pressure has been released, untighten the inlet/outlet nuts into/out of the pump
3.8
PRIMING THE SYRUP PUMP AT THE CORRECT PRESSURE
For the Syrup Pump to operate correctly, it is necessary to remove all air from the system. After all
lines to the Syrup Pump and Syrup Packages are connected and CO
2
(or air pressure) is set, the
system should be primed as follows:
A. Disconnect Wire to Soda Solenoid or close Shut Off Valve on soda side so that only syrup will
be dispensed when Dispensing Valve is operated.
B. Operate Valve for five (5) seconds and then release for five (5) seconds. Continue drawing
syrup until flow is steady and full.
C. After priming, look for air pockets in Syrup Inlet or Outlet Lines. Repeat priming to remove any
air pockets found.
D. After priming, replace the Wire to Soda Solenoid or open Soda Shut Off Valve on Dispensing
Valve.
E. Repeat above procedure for all Syrup Pumps.
3.9
REPLENISHING BIB (BAG-IN-BOX) SYRUP SUPPLY
A. Remove empty Syrup Package from system by turning Collar on Quick Disconnect Coupling
counterclockwise.
B. On a new Package, push in on tab located above perforated opening flap.
C. After breaking seal on flap, pull the flap up.
D. Reach in the box and pull the Bag Valve out. Remove the Dust Cap.
E. Connect the Quick Disconnect Coupling by turning the Collar clockwise until stopped by the Bag
Valve.
F
The Lancer Sold-Out Device will reset automatically.
G. If air has entered the Syrup System, prime the Syrup Pump following the instructions in
Section 3.3