TROUBLESHOOTING GUIDE FOR FS22 DISPENSER

TROUBLE

CAUSE

REMEDY

4.1

No product when

A. Keyswitch is off, or Keyswitch

A. Turn Keyswitch "ON" and/or 

switch is activated.

harness disconnected.

reconnect Keyswitch harness.

(Switch panel does

B.

9-pin

valve harness is

B.

Turn off power

, reconnect 9-pin

NOT

light up when

disconnected.

harness, and restore power.

activated).

C. Faulty switch assembly.

C. Replace switch assembly.

D. No power to unit.

D. Check internal breaker and

incoming power.

4.2

No product when

A.

25-pin

valve harness

A.

Turn off power

, reconnect 25-pin

switch is activated

is disconnected.

harness, and restore power.

(switch panel 

DOES

B. Faulty switch assembly.

B. Replace switch assembly.

light up when activated).

4.3

Push Chute and

A. Dispenser not connected

A. Connect Dispenser to power 

nothing happens.

to power source.

source.

B. Microswitch defective.

B. Replace Microswitch.

C. Wiring Harness not

C. Plug in Wiring Harness.

plugged in.

D. PC Board defective.

D. Replace PC Board.

4.4

Push Chute.  Ice Door

A. Wiring Harness not

A. Plug in Wiring Harness.

opens but Motor does

plugged in.

not run.

B. PC Board defective.

B. Replace PC Board.

C. Motor defective.

C. Replace Motor.

4.5

Push Chute.  Motor

A. Solenoid not connected to

A. Connect Solenoid to PC board.

runs but Ice Door

PC Board.

does not open.

B. Solenoid defective.

B. Replace Solenoid.

C. PC Board defective.

C. Replace PC Board.

D. Solenoid bracket screwed

D. Unscrew solenoid bracket, raise

too low and not opening

solenoid and re-screw bracket.

completely.

4.6

Push Chute, Ice Door

A. Dispenser is out of ice.

A. Fill unit with ice.

opens, Motor runs,

B. Agitator Pin is missing or

B. Replace Agitator Pin.

but no ice dispenses,

damaged.

or ice is of poor quality.

C. Poor ice quality.

C. Install water filtration/purification

to ice maker supply water.

4.7

Valves do not operate.

A. Keyswitch is off, or Keyswitch

A. Turn Keyswitch and/or make sure

harness disconnected.

Keyswitch harness is connected.

B. Circuit Breaker tripped.

B. Reset Circuit Breaker.

C. Unit not plugged in.

C. Plug in Dispenser.

4.8

Water in Ice Bin.

A. Coldplate Drain is obstructed.

A. Remove Splash Plate to obtain

access to Drain tubes and clear
accordingly.

4.9

Water leakage around

A. Damaged or improperly

A. If damaged, replace.  If improperly

nozzle.

installed o-ring on Nozzle.

installed, adjust.

4.10

Miscellaneous leakage.

A. Gap between parts.

A. Tighten appropriate retaining

screws.

B. Damaged or improperly

B. Replace or adjust appropriate

installed O-rings.

O-rings.

4.11

Noisy/Cavitating

A. Insufficient incoming water

A. Verify incoming supply water

Carbonator Pump

supply pressure.

pressure to Carbonator Pump is a

minimum

of 25 psi Carbonator

Pump (maximum of 50 psi).

Summary of Contents for 14400 SERIES

Page 1: ...ancer all rights reserved 6655 LANCER BLVD SAN ANTONIO TEXAS 78219 USA 210 310 7000 FAX SALES NORTH AMERICA 210 310 7245 INTERNATIONAL SALES 210 310 7242 CUSTOMER SERVICE 210 310 7242 LATIN AMERICA 21...

Page 2: ...ITATION IT MAY ACTIVATE UNEXPECTEDLY DO NOT PLACE HANDS OR FOREIGN OBJECTS IN THE ICE STORAGE COMPARTMENT WHEN UNIT IS BEING SERVICED CLEANED OR SANITIZED UNPLUG DISPENSER FROM THE POWER SOURCE NOTE L...

Page 3: ...e __________________________________________ Local Service Phone ________________________________________ ii TABLE OF CONTENTS SPECIFICATIONS i MANUFACTURERS INTRODUCTION ii TABLE OF CONTENTS ii 1 INS...

Page 4: ...t on the floor B Cut band and remove C Open top of carton and remove interior packing D Lift carton up and off of the dispenser E Remove wood shipping base from the bottom of the dispenser Support dis...

Page 5: ...cted to a potable water supply must all be sized installed and maintained according to Federal State and Local laws The water supply must be protected by means of an air gap a backflow prevention devi...

Page 6: ...of the unit See Figure 3 Check for leaks G Connect syrup supply lines to the 3 8 inch barb inlet fittings at the front of the unit See Figure 4 using BIB Bag In Box pumps Check for leaks H Connect fl...

Page 7: ...er equipment identified by this manual If other equipment is being cleaned follow the guidelines established for that equipment B Cleaning and sanitizing should be accomplished only by trained personn...

Page 8: ...le body E Fill a cup with clean warm water and rinse nozzle body F Make certain that the nozzle o ring is not torn or otherwise damaged If necessary replace damaged o ring with LANCER PN 02 0231 G Wet...

Page 9: ...solution Continue rinsing until testing with phenolpthalein shows that the rinse water is free of residual detergent WARNING TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE DO NOT ATTEMPT TO REMO...

Page 10: ...nser NOTE Please note that a fresh water rinse cannot follow sanitization of equipment Purge only with the end use product until there is no after taste in the product This is an NSF requirement L Tes...

Page 11: ...NO PWB C CONFIG BONUS KEY BONUS KEY SETUP V 1 T F M F B F FS 22 NO PWB C CARB WATER SETUP CARB WATER SETUP V1 B1 SODA SOLD OUT 1 OFF FS 22 NO PWB C NUMBER OF VALVES 1 2 Y Y FS 22 NO PWB C GLOBAL CONFI...

Page 12: ...e remote carbonator pump will activate periodically to fill carbonator with the appropriate amount of water NOTE To check for CO2 leaks close the valve on the CO2 cylinder and observe if the pressure...

Page 13: ...rom the system After all lines to the Syrup Pump and Syrup Packages are connected and CO2 or air pressure is set the system should be primed as follows A Disconnect Wire to Soda Solenoid or close Shut...

Page 14: ...id to PC board runs but Ice Door PC Board does not open B Solenoid defective B Replace Solenoid C PC Board defective C Replace PC Board D Solenoid bracket screwed D Unscrew solenoid bracket raise too...

Page 15: ...IB Pump D Replace pump 4 15 Erratic ratio A Incoming water and or syrup A Check pressure and adjust supply not at minimum flowing pressure B Foreign debris in water and or B Remove flow control from s...

Page 16: ...ly seated B Reattach door assembly to dispenser 4 22 Circuit breaker tripping A Valve wire harness es A Detect short by disconnecting valve shorted to itself or Faucet harnesses from Switch Panel Plat...

Page 17: ...w preventer not D Replace backflow preventer allowing water to flow noting the flow direction arrow from pump to coldplate E Probe malfunctioning E Replace Probe F PCB malfunctioning F Replace PCB 5 E...

Page 18: ...15 6 ILLUSTRATIONS AND PARTS LISTINGS 6 1 FINAL ASSEMBLY 1 2 5 6 3 4 9 10 7 8 11 12 14 15 37 36 13 16 17 18 19 20 21 24 22 23 28 29 30 25 26 27 31 32 33 34 35 38...

Page 19: ...Shaft Motor IBD 17 23 1373 Agitator Assy FS IBD HEX 18 05 1555 Bearing Agitator Rear IBD 19 10 0762 Pin Hex Design FS 16 20 03 0368 Retainer Pin Agitator IBD R 21 82 3556 Dispensing Wheel Assy Hex 22...

Page 20: ...03 0368 Retainer Pin Agitator IBD 5 82 3651 Dispensing Wheel Assy Pellet Ice R 6 30 9801 01 Shield Nugget IC R in margin indicates change NOTICE The Pellet Ice components listed on this Instruction S...

Page 21: ...V1 BLACK BLACK WHITE BLACK WHITE BLACK POWER SUPPLY CONTROLLER BOARD DISPLAY CARB AGI FOT COMM ICE OPTIC ICE DOOR ICE SWITCH KEY SOLD OUT JV1 JV2 JV3 JV4 CARB PROBE POWER CARBONATOR BALLAST ICE AGITAT...

Page 22: ...1 YEL BLK RED BLK BRN BLK YEL GRY V A L V E M O U N T I N G N O Z Z L E P A N E L I N L E T F I T T I N G S BLU BLK RED GRY S1 3 SODA1 WATER1 S1 4 S1 2 S1 1 IS1 1 IS1 2 IS1 3 VALVE HARNESS DIAGRAM PLU...

Page 23: ...sia Flat A 24 F Houston Industrial Bldg 32 40 Wang Lung Street Tsuen Wan N T Hong Kong Phone 852 94302585 FAX 852 24082605 e mail patrickco lancer asia com Lancer Authorized Distributors Shanghai Fres...

Page 24: ...Lancer Europe Web Site www lancereurope be Belgium European Central Office Lancer Europe S A Mechelsesteenweg 592 B 1930 Zaventem Belgium Phone 32 2 755 2390 FAX 32 2 755 2399 e mail info lancereurope...

Reviews: