1.3

SELECTING COUNTER LOCATION (SEE FIGURE 1)

WARNING

THIS APPLIANCE MUST BE EARTHED.  THIS DISPENSER MUST BE ELECTRICALLY
GROUNDED TO AVOID DANGER TO THE OPERATOR.  THE POWER CORD PROVIDED HAS
A THREE PRONG GROUNDED PLUG.  IF A THREE HOLED GROUNDED ELECTRICAL
OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD OF INSURING A PROPER
GROUND TO THE DISPENSER.

CAUTION

FAILURE TO DISCONNECT THE MOTOR POWER SUPPLY WILL DAMAGE THE CARBONATOR
MOTOR AND PUMP AND VOID THE WARRANTY.

A. Select a location close to a properly grounded 20 Amp electrical outlet, convenient to an open

type drain, access for soda, water, and syrup lines.  It should have sufficient clearance above
the unit to provide for servicing.

1.

If at all possible, location should be away from direct sunlight or other heat sources.

2.

Connecting lines may be run through access in back of the unit or extend down through a
counter cutout.

3.

Check the dispenser serial number plate for correct electrical requirements of unit.  

Do not

plug into wall electrical outlet unless the current shown on the serial number plate agrees with local
current available.

4.

The counter must support the weight of the dispenser, ice, and possibly an icemaker.  

Total

weight may exceed 

500

 pounds (226.8 kg).

B. Unit may be installed directly on the countertop or on legs supplied with the unit.  If installed

directly on the counter, the unit must be sealed to the countertop.  

If an icemaker is to be 

mounted on top of dispenser, do not install dispenser on legs.

NOTE

Water pipe connections and fixtures directly connected to a potable water supply must all be
sized, installed, and maintained according to Federal, State, and Local laws.

The water supply must be protected by means of an air gap, a backflow prevention device
(located upstream of the CO

2

injection system) or another approved method to comply with NSF

standards.  A backflow prevention device must comply with ASSE and local standards.  

It is the

responsibility of the installer to ensure compliance.

C.

Location must insure sufficient clearance

on sides, top and back of unit is provided for 

ventilation and air circulation (see Figure 1).

D. Additionally, if an ice maker is not top mounted on the unit, sufficient clearance should be 

provided [a minimum of 16 inches (40.6 cm) is recommended] to allow filling the unit with ice
from a five (5) gallon (19 liter) container (see Figure 1).

1.4

INSTALLING THE DISPENSER

A. Remove Cup Rest, Drip Tray, Splash Plate, and Top Cover.
B. Remove Cover Plate at rear of unit if not a through-the counter-installation.
C. Connect water supply for carbonator/plain water to the 3/8 inch flare fittings at the front of the

unit (See Figure 2).

D. For the 

plain water supply line

, the inlet water 

flowing pressure

should be 

at least 75 PSI

.

If the water pressure is lower than 75 psi flowing, a Water Booster system must be used

.

NOTE:

The Lancer Water Booster/Tank, PN 

MC-163172

, is offered as a kit.

The Water Booster must be installed as close as possible to the plain water circuit inlet.

If the water flowing pressure is lower than 75 PSI at the plain water inlet, and a water booster
is NOT installed, all water products will not hold a proper flow rate and/or water/syrup ratio.
Additionally, flow conditions at the nozzle may be affected, for example, poor nozzle coning and
mixing.

2

Summary of Contents for 14400 SERIES

Page 1: ...ancer all rights reserved 6655 LANCER BLVD SAN ANTONIO TEXAS 78219 USA 210 310 7000 FAX SALES NORTH AMERICA 210 310 7245 INTERNATIONAL SALES 210 310 7242 CUSTOMER SERVICE 210 310 7242 LATIN AMERICA 21...

Page 2: ...ITATION IT MAY ACTIVATE UNEXPECTEDLY DO NOT PLACE HANDS OR FOREIGN OBJECTS IN THE ICE STORAGE COMPARTMENT WHEN UNIT IS BEING SERVICED CLEANED OR SANITIZED UNPLUG DISPENSER FROM THE POWER SOURCE NOTE L...

Page 3: ...e __________________________________________ Local Service Phone ________________________________________ ii TABLE OF CONTENTS SPECIFICATIONS i MANUFACTURERS INTRODUCTION ii TABLE OF CONTENTS ii 1 INS...

Page 4: ...t on the floor B Cut band and remove C Open top of carton and remove interior packing D Lift carton up and off of the dispenser E Remove wood shipping base from the bottom of the dispenser Support dis...

Page 5: ...cted to a potable water supply must all be sized installed and maintained according to Federal State and Local laws The water supply must be protected by means of an air gap a backflow prevention devi...

Page 6: ...of the unit See Figure 3 Check for leaks G Connect syrup supply lines to the 3 8 inch barb inlet fittings at the front of the unit See Figure 4 using BIB Bag In Box pumps Check for leaks H Connect fl...

Page 7: ...er equipment identified by this manual If other equipment is being cleaned follow the guidelines established for that equipment B Cleaning and sanitizing should be accomplished only by trained personn...

Page 8: ...le body E Fill a cup with clean warm water and rinse nozzle body F Make certain that the nozzle o ring is not torn or otherwise damaged If necessary replace damaged o ring with LANCER PN 02 0231 G Wet...

Page 9: ...solution Continue rinsing until testing with phenolpthalein shows that the rinse water is free of residual detergent WARNING TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE DO NOT ATTEMPT TO REMO...

Page 10: ...nser NOTE Please note that a fresh water rinse cannot follow sanitization of equipment Purge only with the end use product until there is no after taste in the product This is an NSF requirement L Tes...

Page 11: ...NO PWB C CONFIG BONUS KEY BONUS KEY SETUP V 1 T F M F B F FS 22 NO PWB C CARB WATER SETUP CARB WATER SETUP V1 B1 SODA SOLD OUT 1 OFF FS 22 NO PWB C NUMBER OF VALVES 1 2 Y Y FS 22 NO PWB C GLOBAL CONFI...

Page 12: ...e remote carbonator pump will activate periodically to fill carbonator with the appropriate amount of water NOTE To check for CO2 leaks close the valve on the CO2 cylinder and observe if the pressure...

Page 13: ...rom the system After all lines to the Syrup Pump and Syrup Packages are connected and CO2 or air pressure is set the system should be primed as follows A Disconnect Wire to Soda Solenoid or close Shut...

Page 14: ...id to PC board runs but Ice Door PC Board does not open B Solenoid defective B Replace Solenoid C PC Board defective C Replace PC Board D Solenoid bracket screwed D Unscrew solenoid bracket raise too...

Page 15: ...IB Pump D Replace pump 4 15 Erratic ratio A Incoming water and or syrup A Check pressure and adjust supply not at minimum flowing pressure B Foreign debris in water and or B Remove flow control from s...

Page 16: ...ly seated B Reattach door assembly to dispenser 4 22 Circuit breaker tripping A Valve wire harness es A Detect short by disconnecting valve shorted to itself or Faucet harnesses from Switch Panel Plat...

Page 17: ...w preventer not D Replace backflow preventer allowing water to flow noting the flow direction arrow from pump to coldplate E Probe malfunctioning E Replace Probe F PCB malfunctioning F Replace PCB 5 E...

Page 18: ...15 6 ILLUSTRATIONS AND PARTS LISTINGS 6 1 FINAL ASSEMBLY 1 2 5 6 3 4 9 10 7 8 11 12 14 15 37 36 13 16 17 18 19 20 21 24 22 23 28 29 30 25 26 27 31 32 33 34 35 38...

Page 19: ...Shaft Motor IBD 17 23 1373 Agitator Assy FS IBD HEX 18 05 1555 Bearing Agitator Rear IBD 19 10 0762 Pin Hex Design FS 16 20 03 0368 Retainer Pin Agitator IBD R 21 82 3556 Dispensing Wheel Assy Hex 22...

Page 20: ...03 0368 Retainer Pin Agitator IBD 5 82 3651 Dispensing Wheel Assy Pellet Ice R 6 30 9801 01 Shield Nugget IC R in margin indicates change NOTICE The Pellet Ice components listed on this Instruction S...

Page 21: ...V1 BLACK BLACK WHITE BLACK WHITE BLACK POWER SUPPLY CONTROLLER BOARD DISPLAY CARB AGI FOT COMM ICE OPTIC ICE DOOR ICE SWITCH KEY SOLD OUT JV1 JV2 JV3 JV4 CARB PROBE POWER CARBONATOR BALLAST ICE AGITAT...

Page 22: ...1 YEL BLK RED BLK BRN BLK YEL GRY V A L V E M O U N T I N G N O Z Z L E P A N E L I N L E T F I T T I N G S BLU BLK RED GRY S1 3 SODA1 WATER1 S1 4 S1 2 S1 1 IS1 1 IS1 2 IS1 3 VALVE HARNESS DIAGRAM PLU...