11
A
B
A. Oetiker Pliers
B. Tubing
C. Syrup/Water Inlet
C
Dispenser Installation - 2200 & 23300
The installation or relocation of the dispenser must
be carried out by qualified personnel with up-to-date
knowledge and practical experience, in accordance with
current regulations.
NOTE
1. Inspect the counter location where the unit is to be installed,
then make counter cutout (see
Specifications
section on
pages 4 and 7 or Cutout Diagrams on back of manual for
counter cutout dimensions).
Counter cutout must be accurate, according to unit
specifications.
!
ATTENTION
2. Once the counter cutout is made, lower the unit into the
counter and seal rim to the counter using an approved
silicone sealant.
3. Route appropriate tubing from the water source to the water
inlets at the front of the unit.
4. Install “U” fitting to water line to split between soda and
plain water lines.
A
B
C
D
A. “U” Fitting
B. Line from Water Source
C. Line to Soda Water Inlet
D. Line to Plain Water Inlet
The unit can extend up to 23 inches (58.42 cm) below
the counter, including the shipping risers, which
Lancer recommends be left attached to the unit. Should
the dispenser ever require removal, the shipping risers
will protect the inlet tubes from being damaged.
NOTE
6. Connect tubing to water source then flush water lines to
check for leaks.
7. Install water regulator and filter to water line and, if
necessary, install water booster (Lancer PN MC-163172)
between water supply and the unit.
8. Using tubing cutters, cut soda water line and install remote
carbonator per manufacturer’s specifications (see
General
System Overview
on pages 8 for reference).
9. Install a shutoff valve in the water line feeding the remote
carbonator.
10. Connect each syrup line to appropriate syrup inlet in the
front of the unit (see
Plumbing Diagrams
on the front of the
unit or on pages 29-32 for reference).
11. Connect each syrup line to individual syrup pump outlet
fitting.
12. Install BIB connectors to the syrup supply line tubing.
5. Connect tubing of soda and plain water lines to appropriate
inlets, at the front of the unit, using Oetiker pliers and fittings
(see Plumbing Diagrams on the front of the unit or on pages
29-32 for reference).