15
28-0752/02
2.8 RATIO PROCESS
STEP 1:
Remove outer nozzle and insert MVU separator if not done on previous step.
STEP 2:
Prime separator by running the valve.
STEP 3:
Press and fill the ratio cup to the appropriate levels.
STEP 4:
Check/adjust ratio on each brand. Use flow controls to adjust syrup.
STEP 3
Remove outer nozzle and insert syrup
separator (Lancer PN 82-3964/01). This is
important to do during flow rate check so
you can determine if the separator has been
properly installed.
NOTE:
Water will leak through to the syrup
chamber if not properly installed.
Place a ratio cup under the nozzle and
press a brand button.
The brand’s water module will open and
pour for 4 seconds.
NOTE:
Only water will pour during the flow
rate check.
Check for 15 oz of water in the ratio cup.
If above or below 15 oz, adjust the water
Summary of Contents for 23308 SERIES