12
Adjust Water Flow Rate & Syrup/Water Ratio - LFCV
Volumetric Valve Adjustment
1. Remove nozzle by twisting counterclockwise and pulling
down.
2.
Install Lancer syrup separator (PN 05-2919) in place of
nozzle.
3.
Close syrup shut-off at mounting block for syrup brands
4. Using a Lancer ratio cup verify water flow rate (14 oz. in 8
sec.). Use a screwdriver to adjust if needed.
Adjustment of volumetric valves for the Unicorn
Tower requires the use of the Volumetric Handheld
Programmer and Selector Board (PN 64-5050). The
programmer is sold separately for VV programming
only.
NOTE
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
5. Re-open syrup shut-off at mounting block.
6. Using a Lancer ratio cup, activate the valve and capture a
sample. Verify that the syrup level is even with the water
level. Use a screwdriver to adjust if needed.
7. Repeat process for each syrup brand.
8. Remove syrup separator and re-install nozzle.
A
A
B
B
C
C
A. Syrup Separator
B. Ratio Cup
C. Verify Soda/
Water Level
A. Connect to Main Board
B. Connect Volumetric
Programmer
C. Toggle
1. Connect the Volumetric Handheld programmer to the
Selector Board.
2.
Unplug the unit’s Ribbon Cable (52-3346) from the unit’s
main board, and plug the Selector Board cable in its’ place.
(See image on previous page or wiring diagram on page
27-28 for reference)
3. Select the valve to program by adjusting the toggle on the
Selector Board.
4.
Press [red mem] to read the valve ratio setting in memory.
5.
Press [carb toggle] button to choose between carbonated
(C) or non-carbonated drink (n).
6. Press [+] or [-] to raise or lower desired ratio.
7. Press ‘enter’ button to save the setting into the valve
memory.
8. Repeat Steps 3-7 for the remaining 3 valves, then plug the
unit’s ribbon cable (52-3346) back into the Main Board.
Summary of Contents for 85-3151R-20-11111-22
Page 27: ...27 Wiring Diagram LFCV...
Page 28: ...28 Wiring Diagram VV...
Page 29: ...29 Counter Cutout Not to Scale...