H. If out of spec (finished product volume does not equal water volume), adjust the ratio by
pushing the * and
#
buttons: For example:
1. If the ratio is 4 bands below, toggle down to -4 using the * and
#
buttons (see Figure 13).
Press pour cancel and check volume again - Repeat until correct.
2. If the ratio is 3 bands above water level, toggle up to +3. Press pour cancel and check
volume again.
3. When the volume of combined product equals the water level, turn key switch to run position
and return unit to service.
NOTE:
This process should only be performed during startup, pump replacement or changing of
brand.
Figure 13
2.4
DISPENSING CONFIGURATIONS
The dispenser has two (2) different dispensing configurations, depending on the model. These
configurations are:
A.
PUSH and HOLD.
The is the basic machine where the touch sensor switch is pushed to start
dispensing and released to terminate the dispense.
B.
PORTION CONTROL.
This option has a different touch sensor switch and switch control board.
Each valve can be individually programmed to remember four (4) different dispense volumes
and then to dispense those volumes when the individual sections of the touch sensor switch is
activated.
2.5
OPERATION WITH “PUSH and HOLD”
A. Place a vessel on the target located on the Cup Rest.
B. Depress the “Push” area to start the flow of product.
C. Release the pressure on the switch to terminate the flow of product.
2.6
OPERATION WITH “PORTION CONTROL”
A. Place a vessel on the target located on the Cup Rest.
B. Activate the program mode for that valve by simultaneously depressing the “SMALL” and
“EXTRA LARGE” buttons.
C. Place a glass of the proper size (i.e., small, medium, large, or extra large) on the target on the
Cup Rest and depress the corresponding button.
D. Continue holding the button until the proper fill level is obtained.
E. Use the same procedure for setting the fill volume for the other sizes of glasses.
F.
Push the “POUR/CANCEL” button to exit the program mode. The program will automatically
store the last fill volume that was dispensed through that button size before you exited the
program mode.
(This section continued on next page)
6
Summary of Contents for 85-3322
Page 37: ...7 13 ASSEMBLED UNIT 34...