BEV85 Quarterly Service
Work Instruction
Why
Condition and operational service of the BEV85 Oil Free Air Compressor
Time required
20 minutes to complete
Hazard icons
Tools and supplies
Videos are available to support this equipment from Hoshizaki Lancer.
Please see:
www.lancerbeverage.com
Overview:
https://youtu.be/-pKwifqzQEY
Troubleshooting:
https://youtu.be/OobMs8csyj0
Service:
https://youtu.be/_jS9Mm8xmXQ
Safety
Glasses
Paper
Towel
Gloves
Tools
Cleaning
alcohol
Soapy water
Procedure
1
Change Over to CO2 supply
Switch main Beverage Control
Panel over to back-up CO2
supply.
2
Isolate Air Compressor
–
Electrical
Press the red button on the
pressure switch to turn off the
compressor.
Isolate and disconnect the
electrical lead from the wall
socket.
3
Isolate Air Compressor
–
Air Supply
Turn the supply air tap off, ¼
turn. The red handle will be 90
degrees to the hose when off.
4
Drain air tank
Drain the air tank through the
Drain Cock on the base of the
receiver tank.
Turn Clockwise, slowly loosen
Drain Cock to release
compressed air.
Monitor for excessive
moisture draining from the
tank.
Compressed air use of Gloves
& safety glasses is required.
Replace Tank Drain Cock
Wipe drain cock clean.
Refit drain cock, turning anti-
clockwise, ensure finger tight
fitment.
5
Inspect and Drain Regulator
Filter bowl.
Check the condition of the
condensation bowl at the base
of the Filter Regulator.
If dirty and/or more than
10mm of moisture present
remove & clean.