Page 1 of 4 

Images are for illustration purposes only as product may vary. 

No 074  

–  1 November 2018

 

BEV85 Annual Operational Service 

Work Instruction 

 

Why 

Annual Operational Service 

– Filters, Non Return Valve & Compressor Head 

Time required 

40-60 minutes to complete 

 

Hazard icons 

 

 

   

      

 

Tools and supplies 

 

 
 

 

        

PH2

 

         5mm

 

 

 

 

  

Videos are available to support this 
equipment from Hoshizaki Lancer. Please 
see… 

www.lancerbeverage.com 

Overview: 

https://youtu.be/-pKwifqzQEY 

 

Troubleshooting: 

https://youtu.be/OobMs8csyj0 

 

Service: 

https://youtu.be/_jS9Mm8xmXQ

 

Safety Glasses 

Paper Towel 

Gloves 

Tools 
- PH2 Screw Driver 
- Adjustable Spanner 
- 5mm Allen Key 

Cleaning 

alcohol 

Soapy water  Annual Service Kit 

#80000204 

Loctite® 222 

Procedure

 

Change Over to CO2 supply 

Switch main Beverage Control 
Panel over to back-up CO2 
supply. 
 

 

Isolate Air Compressor 

– 

Electrical 

 

Press the red button on the 
pressure switch to turn off the 
compressor.   
 
Isolate and disconnect the 
electrical lead from the wall 
socket. 
 

 

 

Isolate Air Compressor 

–  

Air Supply 

Turn the supply air tap off, ¼ 
turn. The red handle will be 90 
degrees to the hose when off. 

 

Drain air tank 

 

Drain the air tank through the 
Drain Cock on the base of the 
receiver tank.  
 
Turn Clockwise, slowly loosen 
Drain Cock to release 
compressed air.  
Monitor for excessive 
moisture draining from the 
tank. 

 

Compressed air use of Gloves 
& safety glasses is required. 

 

 

 

Replace Tank Drain Cock 

Wipe drain cock clean.   
 
Refit drain cock, turning anti-
clockwise, ensure finger tight 
fitment.  

 

Inspect and Drain Regulator 
Filter bowl. 

Check the condition of the 
condensation bowl at the base 
of the Filter Regulator. 
If dirty and more than 10 mm 
of moisture present remove & 
Clean.

 

 

 

 