background image

Bevariety™ ACIB Dispenser 22”/30”/44”

LANCER INSTALLATION GUIDE

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access to other Technical Documents and alternative translations (if available) pertaining to this unit. Contact Lancer 

Customer Service for assistance as required.

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit,  

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS

LANCER PN: 28-0953/02

The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should 

not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given  

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 

90°F (4°C to 32°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained 

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

MCY-22

MCY-30

Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.

 Do not plug 

into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local 

electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with 

this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to 

the transformer primary. Always disconnect electrical power to the unit  to  prevent  personal injury before attempting any internal 

maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source 

to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all 

water lines are tight and units are dry before making any electrical connections!

Electrical Warning

Summary of Contents for Bevariety ACIB Series

Page 1: ...s not a toy Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons inclu...

Page 2: ...local standards It is the responsibility of the installer to ensure compliance Water Notice Units are equipped with an automatic agitation system and will activate unexpectedly Do not place hands or f...

Page 3: ...chilled products 30 only or two chilled and one ambient product on each MVU pad Capable of dispensing flavor shots Replaces the two center LEVs Provides additional carb or non carb beverage flexibili...

Page 4: ...ack and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the remaining three sides Level unit if necessa...

Page 5: ...the left side wall Dispenser Installation The installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with...

Page 6: ...ocation to the tee fitting at water line 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection installed in the previous...

Page 7: ...aking connections Each dispenser must have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING A Regulator Adjustment Screw B...

Page 8: ...ctivate valve to purge syrup until steady flow is achieved 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwdriver...

Page 9: ...press the Push button one time to change to a non carb beverage 3 Press the same brand button again to change to a carbonat ed beverage light will flash slowly 4 Press the button one more time to chan...

Page 10: ...n to capture a sample Self Serve Crew Serve 8 Verify that the syrup level is even with the water level Use screwdriver to adjust appropriate LFCV if necessary 9 Repeat steps 7 8 for each brand on MVU...

Page 11: ...save 60 seconds after all changes have been made NOTE 5 Repeat Steps 2 4 for each of the desired brands 6 Press the Pour Cancel button to save Cleaning Solution Mix a mild non abrasive detergent e g...

Page 12: ...lush solution from the dispenser Cleaning and Sanitizing Syrup Lines Figal Tank 1 Disconnect syrup inlet from the figal syrup tank 2 Prepare cleaning solution and using a plastic bristle brush scrub b...

Page 13: ...off power to the dispenser 2 Remove Merchandiser 3 Remove Ice Chute Lever then remove Splash Plate Assembly by lifting it up and out from the dispenser face 4 Remove the Ice Chute Assembly base by rem...

Page 14: ...14 WIRING DIAGRAMS ACIB 22 30...

Page 15: ...15 PLUMBING DIAGRAMS ACIB 22 30...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: