Dispenser Installation
1.
Remove the cup rest, drip tray, splash plate, merchandiser,
and top cover from the unit.
2.
Route appropriate tubing from the water source to the plain
water inlet at the front of the unit and connect tubing to inlet
using the oetiker pliers and fittings,(see Plumbing Diagrams
on the front of the unit or on pages 26-27 for reference).
A
B
C
A. CO
2
Inlet
B. Fitting
C. Tubing
4.
Route appropriate tubing from the remote pump deck to the
carbonated water inlet and connect tubing to inlet.
5.
Route appropriate tubing from the syrup pump location to
the syrup inlets and connect tubing to all syrup inlets.
6. For units with a flavor shot module, route appropriate tubing
from the flavor shot pump location to the flavor shot inlets at
the front of the unit and connect tubing to inlets.
7.
Route appropriate tubing from the CO
2
source location to
the CO
2
inlet on the unit and connect tubing to inlet.
A
B
C
A. Oetiker Pliers
B. Fitting
C. Tubing
D. Syrup/Water
Inlet
D
3.
Connect tubing to water source then flush water lines to
check for leaks.
Installing an Icemaker (if necessary)
When installing an icemaker on the dispenser, use
a bin thermostat to control the ice level (see below).
This will prevent damage to the dispensing
mechanism. The bracket for mounting a thermostat is
located in the ice bin. During the automatic agitation
cycle and while dispensing ice, ensure there is ade-
quate space between the top of the ice level and the
bottom of the icemaker so the ice can move without
obstruction. Contact your icemaker manufacturer for
information on a suitable bin thermostat.
!
ATTENTION
1.
Install the icemaker per manufacturer specifications. Points
of consideration include drainage, ventilation, and drop
zones.
2.
An adapter plate is required when installing an icemaker.
Contact your Sales Representative or Lancer Customer
Service for more information.
Failure to use an ice bin thermostat will not only void
your IBD’s warranty but will result in the inability to
control the level of ice in the ice bin which can cause
damage to your dispenser.
!
ATTENTION
3.
A bin thermostat is required in order to control the level of
ice in the dispenser (Refer to ATTENTION). Contact your
icemaker manufacturer to obtain the correct bin thermostat.
4.
Bin thermostat should be a minimum of 2” below the top
edge of the dispenser. The preferred location of the bin
thermostat is on the left side wall.
5.
Ensure the icemaker is installed properly to allow for
removal of the Merchandiser.
6. Ensure manual fill is accessible.
7. Clean and maintain icemaker per manufacturer’s
instructions.
4”
Attach Bin Stat Bracket As Shown
Recommended Bin Stat Attachment
Bulb