22
TROUBLE
CAUSE
REMEDY
BIB pump does not operate
when dispensing valve is
opened.
1. Out of CO
2
, CO
2
not turned on, or low CO
2
pressure.
2. Out of syrup.
3. BIB connector not tight.
4. Kinks in syrup or gas lines.
1.
Replace CO
2
supply, turn on CO
2
supply, or adjust CO
2
pressure to 70-80
PSI (0.483-0.552 MPA).
2.
Replace syrup supply.
3. Fasten connector tightly.
4. Straighten or replace lines.
BIB pump operating, but no
flow.
1. Leak in syrup inlet or outlet line.
2. Defective BIB pump.
1.
Replace line.
2.
Replace BIB pump.
BIB pump continues to operate
when bag is empty.
1. Leak in suction line.
2.
Leaking o-ring on pump inlet fitting.
3. Defective syrup BIB pump.
1. Check BIB connector, if still leaking then
replace line.
2.
Replace o-ring
3.
Replace defective pump.
BIB pump fails to restart after
bag replacement.
1. BIB connector not on tightly.
2. BIB connector is stopped up.
3. Kinks in syrup line.
1. Tighten BIB connector.
2. Clean out or replace BIB connector.
3. Straighten or replace line.
BIB pump fails to stop when
dispensing valve is closed.
1.
Leak in discharge line or fittings.
2. Empty BIB.
3. Air leak on inlet line or bag connector.
1.
Repair or replace discharge line.
2.
Replace BIB.
3.
Repair or replace.
Remote Syrup/Flavor Shot Pump Troubleshooting