background image

3

• 

The dispenser is for indoor use only

• 

This appliance is intended to be used in commercial 

applications such as restaurants or similar.

• 

This appliance should not be used by children or 

infirm persons without supervision. 

• 

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and       

knowledge, unless they have been given supervision 

or instruction concerning use of the appliance by a 

person responsible for their safety. 

• 

This appliance can be used by children aged from 8 

years and above and persons with reduced physical, 

sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or 

instruction concerning use of the appliance in a safe 

way and understand the hazards involved.

• 

Cleaning and user maintenance shall not be          

performed by children without supervision.

• 

This unit is not a toy and children should be advised 

not to play with the appliance.

• 

The min/max ambient operating temperature for the 

dispenser is 40°F to 105°F (4°C to 41°C). 

• 

Do not operate unit below minimum ambient operation 

conditions. 

• 

Should freezing occur, cease operation of the unit and 

contact authorized service technician.

• 

The maximum tilt for safe operation is 5°. 

• 

This appliance must be installed and serviced by a 

professional.

Intended Use

• 

Follow all local electrical codes when making         

connections.

• 

Check the dispenser name plate label, located behind 

the splash plate, for the correct electrical requirements                                                                                   

of unit.

 

DO NOT

 plug into a wall electrical outlet 

unless the current shown on the serial number plate 

agrees with local current available.

• 

Each dispenser must have a separate electrical 

circuit. 

•  DO NOT

 use extension cords with this unit.  

•  DO NOT

 ‘gang’  together with other electrical devices 

on the same outlet.

•  WARNING: 

Always disconnect electrical power to the 

unit to prevent personal injury before attempting any 

internal maintenance. 

• 

The resettable breaker switch should not be used as 

a substitute for unplugging the dispenser from the 

power source to service the unit. 

• 

Only qualified personnel should service internal    

components of electrical control housing. 

•  WARNING: 

Make sure that all water lines are tight and 

units are dry before making any electrical connections 

• 

If this dispenser is installed in an area that is          

susceptible to ±10% variation of the nominal line    

voltage, consider installing a surge protector or similar 

protection device.

Power

IMPORTANT SAFETY INSTRUCTIONS

•  WARNING:

 Carbon Dioxide (CO2) is a colorless,      

noncombustible gas with a light pungent odor. High 

percentages of CO

2

 may displace oxygen in the 

blood. 

•  WARNING: 

Prolonged exposure to CO

2

  can  be  harmful.           

Personnel exposed to high concentrations of CO

2

 gas 

will experience tremors which are followed by a loss 

of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately 

ventilate the contaminated area before attempting to 

repair the leak. 

•  WARNING: 

Strict attention must be observed in the 

prevention of CO

2

 gas leaks in the entire CO

2

 and soft 

drink system.

Carbon Dioxide (CO

2

)

• 

Provide an adequate, potable water supply. Water 

pipe connections and fixtures directly connected to 

a potable water supply must be sized, installed, and 

maintained according to federal, state, and local 

codes.

• 

The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimym of 25 PSI (0.172 

MPA) line pressure, but not exceeding a maximum of 

65 PSI (0.448 MPA).  Water pressure exceeding 65 

PSI (0.448 MPA) must be reduced to 65 PSI (0.448 

MPA).

• 

Use a filter in the water line to avoid equipment 

damage and beverage off-taste. Check the water filter 

periodically, as required by local conditions.

•  CAUTION: 

The water supply must be protected by 

means of an air gap, a backflow prevention device  

(located upstream of the CO

2

 injection system) 

or another approved method to comply with NSF           

standards. A leaking inlet water check valve will         

allow carbonated water to flow back through the pump 

when it is shut off and contaminate the water supply.

•  CAUTION: 

Ensure the backflow prevention device   

complies with ASSE and local standards. It is the 

responsibility of the installer to ensure compliance.

Water Notice

Summary of Contents for Blue Star CB Series

Page 1: ...l rights reserved 4500 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Tech Support Warranty 800 729 1550 email custserv lancercorp com web lancercorp com Lancer PN 28 0946 03...

Page 2: ...Bin Ice Chute Carbonator Pump Troubleshooting 21 Remote Syrup Flavor Shot Pump Troubleshooting 22 ILLUSTRATIONS AND PART LISTINGS 23 27 Main Unit Assembly 22 25 30 23 Flavor Shot Module Assembly 24 P...

Page 3: ...d as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure tha...

Page 4: ...SIONS Width 22 0 inches 559 mm Depth 30 5 inches 775 mm Height 40 25 inches 1022 mm WEIGHT Shipping 310 lbs 141 kg Empty without Ice 280 lbs 127 kg Ice Capacity 200 lbs 91 kg ELECTRICAL 115 VAC 60 Hz...

Page 5: ...3 6 Amps PLAIN WATER SUPPLY Min Flowing Pressure 75 PSIG 0 516 MPA CARBONATED WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max Static Pressure 65 PSI 0 448 MPA CARBON DIOXIDE CO2 SUPPLY Min Pres...

Page 6: ...PSIG 0 516 MPA CARBONATED WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max Static Pressure 65 PSI 0 448 MPA CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 M...

Page 7: ...Closed B Carb Water ON E Syrup Closed C Syrup ON D There is 100 flexibility on the 22 6 valve and the 30 8 valve dispensers The 30 10 valve and the 25 8 valve dispensers have space restrictions so th...

Page 8: ...ubing Oetiker Clamp Fittings Water Booster Lancer PN 82 3401 or MC 163172 Water Regulator supplied with unit CONSIDER THE FOLLOWING BEFORE INSTALLATION Location of Water Supply Lines Location of Drain...

Page 9: ...flake ice in the dispenser NOTE The dispenser should only be installed in a location where it can be overseen by trained personnel NOTE 4 Unit may be installed directly on countertop or on legs If ins...

Page 10: ...spensing mechanism The bracket for mounting a thermostat is located in the ice bin During the automatic agitation cycle and while dispensing ice ensure there is ade quate space between the top of the...

Page 11: ...to drain may cause the Drain Tube to become clogged with coffee or tea grounds or other solid particles ATTENTION Remote Pump Installation 1 If necessary install water booster Lancer PN MC 163172 betw...

Page 12: ...the tee fitting at syrup pumps A B C A Syrup Pump Outlet B Syrup Pump C Fitting 4 Connect tubing from dispenser syrup inlet to the syrup pump outlet fitting Repeat for each syrup line pump and flavor...

Page 13: ...ubing routed from the tee at the syrup pumps to the second outlet of the low pressure CO2 regulator manifold 7 Repeat Step 6 for both low pressure CO2 regulators on the regulator manifold routed to th...

Page 14: ...mately 1 2 of the bin before plugging in the unit 5 Connect unit power cord to grounded electical outlet A Pressure Relief Valve B CO2 Inlet C Valve Lever A B C 9 Turn on CO2 at the source then using...

Page 15: ...g counter clockwise and pulling down then remove diffuser by pulling down 5 Install Lancer yellow syrup seperator PN 54 0031 in place of nozzle 6 Re open syrup shut off at mounting block 7 Activate va...

Page 16: ...ng solution is removed from the system ATTENTION Cleaning and Sanitizing Solutions Cleaning Solution Mix a mild non abrasive detergent e g Sodium Laureth Sulfate dish soap with clean potable water at...

Page 17: ...Activate each valve until lines are filled with cleaning solution then let stand for ten 10 minutes 7 Flush out cleaning solution from the syrup lines using clean warm water 1 Disconnect the four 4 fl...

Page 18: ...sanitizing solution and let sit for fifteen 15 minutes 6 Set nozzle and diffuser aside and let air dry DO NOT rinse with water after sanitizing 7 Reconnect diffuser and nozzle 8 Connect power 9 Taste...

Page 19: ...ated 1 Keyswitch is off or keyswitch harness is disconnected 2 No power to dispenser 3 Malfunctioning switch assembly 4 Malfunctioning power supply 5 Malfunctioning PCB board 6 Malfunctioning VersaPou...

Page 20: ...ply Adjust CO2 pressure to 70 PSI 0 483 MPA 2 Need water booster kit 3 Replace carbonator pump 4 Replace backflow preventer noting the flow direction arrow from pump to coldplate 5 Replace probe 6 Rep...

Page 21: ...obstructed 1 Remove splash plate and drip tray to obtain access to drain tubes and clear accordingly Push ice chute no response 1 Dispenser not connected to power source 2 Wiring harness not plugged...

Page 22: ...continues to operate when bag is empty 1 Leak in suction line 2 Leaking o ring on pump inlet fitting 3 Defective syrup BIB pump 1 Check BIB connector if still leaking then replace line 2 Replace o rin...

Page 23: ...Merchandiser Sub Assy IBD22 05 3357 01 Merchandiser Sub Assy IBD30 7 64 5031 01 01 PCB Assy Backlight Part No Description 85 4528CB 211P IBD25 4500 115 60 8V 85 4546CB 211P IBD22 4500 115 60 6V 85 454...

Page 24: ...nel Assembly 7 04 0774 Thumb Screw 8 30 12838 Flavor Shot Bracket 3 10 11 12 13 8 14 9 17 18 6 2 1 16 15 4 5 7 Flavor Shot Module Assembly 9 05 1385 Elbow Fitting 0 5 Dole x 0 2 Barb 10 19 0262 03 LFC...

Page 25: ...25 Plumbing Diagram 22 Plumbing Diagram 25 Syrup Lines Not Shown Syrup Lines Not Shown...

Page 26: ...26 Plumbing Diagram 30 8 Valve Plumbing Diagram 30 10 Valve Syrup Lines Not Shown Syrup Lines Not Shown...

Page 27: ...to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal o...

Page 28: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: