13
Monthly
• Unplug the dispenser from the power source.
• Remove the bonnet and clean the dirt from the gas cooler using a soft brush.
• Replace the bonnet and plug in the unit.
Every Six Months
• Clean and sanitize the unit using the appropriate procedures outlined in the Cleaning and
Sanitizing section of this manual.
Yearly
• Clean water bath interior, including evaporator coils and refrigeration components.
• Clean the entire exterior of the unit.
Following sanitization, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing solution
left in the system creates a health hazard.
!
CAUTION
Cleaning and Sanitizing Nozzles
A
B
C
A. Nozzle
B. Diffuser
C. Soda Lever
1. Disconnect power, so as to not activate valve while cleaning.
2. Remove nozzle by twisting counter clockwise and pulling
down.
3.
Remove diffuser by pulling down.
4. Rinse nozzle and diffuser with warm water.
5.
Wash nozzle and diffuser with cleaning solution then
immerse in sanitizing solution and let sit for fifteen (15)
minutes.
6.
Set nozzle and diffuser aside and let air dry.
DO NOT
rinse
with water after sanitizing.
7.
Reconnect diffuser and nozzle.
8. Connect power.
9.
Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
Cleaning and Sanitizing Syrup Lines - BIB
1. Disconnect syrup lines from BIB’s
2. Place syrup lines, with BIB connectors, in a bucket of warm
water.
3.
Activate each valve to fill the lines with warm water and flush
out syrup remaining in the lines.
4.
Prepare Cleaning Solution described above.
5. Place syrup lines, with BIB connectors, into cleaning
solution.
6.
Activate each valve until lines are filled with cleaning solution
then let stand for ten (10) minutes.
7.
Flush out cleaning solution from the syrup lines using clean,
warm water.
Following sanitization, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing solution
left in the system creates a health hazard.
!
CAUTION
8. Prepare Sanitizing Solution described above.
9. Place syrup lines into sanitizing solution and activate each
valve to fill lines with sanitizer. Let sit for ten (10) minutes.
10.
Reconnect syrup lines to BIB’s and draw drinks to flush
solution from the dispenser.
11.
Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.