3

CARBON DIOXIDE (CO

2

) SUPPLY

 

Min Pressure

: 70 PSIG (0.483 MPA)

 

Max Pressure

: 80 PSIG (0.552 MPA)

FITTINGS

 

Carbonator Inlet

: 3/8 inch barb

 

Plain Water Inlet

: 3/8 inch barb

 

Brand Syrup Inlets

: 3/8 inch barb

 

CO

2

 Inlet

: 3/8 inch barb

DIMENSIONS

 

Width

: 19.5 inches (495 mm)

 

Depth

: 28.5 inches (724 mm)

 

Height

: 27.75 inches (705 mm)

WEIGHT

 

Shipping

: 211 lbs (95.7 kg)

 

Empty

: 166 lbs (75.3 kg)

 

Operating

: 246 lbs (111.5 kg)

ELECTRICAL

 

115 VAC / 60 Hz / 7.9 Amps

 

230 VAC / 50 Hz / 3.1 Amps

 

220 VAC / 60 Hz / 3.8 Amps

 

PLAIN WATER SUPPLY

 

Min Flowing Pressure

: 75 PSIG (0.516 MPA)

CARBONATED WATER SUPPLY

 

Min Flowing Pressure

: 25 PSI (0.172 MPA)

 

Max Static Pressure

: 50 PSI (0.345 MPA)

Lit Merchandiser Specifications

This unit emits a sound pressure level below 70 dB

INSTALLATION

Unpack the Dispenser

1.  Cut package banding straps and remove.
2.  Open the box and remove the parts tray.
3.  Close the lid, then remove using the handle cutouts.
4.  Remove accessory kit and loose parts.

 

Inspect unit for concealed damage. If evident, notify 

 

delivering carrier and file a claim against the same.

NOTE

 

If unit is to be transported, it is advisable to leave the 

unit secured to the plywood shipping base.

NOTE

5.  Remove plywood shipping base from unit by moving unit so 

that one side is off the counter top or table allowing access 

to screws on the bottom of the plywood shipping base.

6.  If leg kit has been provided, assemble legs by tilting unit.

 

DO NOT LAY UNIT ON ITS SIDE OR BACK

ATTENTION

 

Failure to maintain specified clearance will cause the 

 

compressor to overheat and will result in compressor 

 failure

ATTENTION

Selecting/Preparing Counter Location

 

The dispenser should only be installed in a location 

where it can be overseen by trained personnel

NOTE

1.  Select a location that is in close proximity to a properly 

grounded electrical outlet, within five (5) feet (1.5 m) of 

a drain, and a water supply that meets the requirements 

shown in the Specifications section found on the previous 

page. 

2.  Select a location for the syrup pumps, CO

2

 tank, syrup     

containers, and water filter (recommended).

3.  Condenser air is drawn in from the front and side vents      

located on the bonnet and dischargede out the rear of the 

bonnet. A minimum of eight (8) inches (203 mm) of clearance 

must be maintained over the top of the unit and a minimum 

of four (4) inches (101.6 mm) clearance behind the unit to 

provide for proper air flow and circulation.

 

Lancer recommends placing counter cut-out toward

 

the front of the unit’s designated location due to the 

 

syrup/water/CO2 inlets being located behind the 

 

splash plate in the front of the unit. 

NOTE

4.  Cut a nine and a half (9.5) inch (241.3 mm) by two (2) inch 

(50.8 mm) rectangular hole, one (1) inch (25.4 mm) from the 

back wall in the designated dispenser location. 

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Numer:

This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this 

dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your 

Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

Summary of Contents for DELTA6 Series

Page 1: ...to the dispenser lies with the carrier The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowledge and practica...

Page 2: ...63 0 kg Operating 219 lbs 99 3 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand...

Page 3: ...e compressor to overheat and will result in compressor failure ATTENTION Selecting Preparing Counter Location The dispenser should only be installed in a location where it can be overseen by trained p...

Page 4: ...mp location to the syrup inlets located behind the splash plate Connect tubing to inlets using the oetiker pliers and fittings Repeat for all syrup connections If the unit being installed has built in...

Page 5: ...riate tubing from the syrup pump syrup supply location to the CO2 inlet and connect tubing to CO2 inlet If the water source is above 50 PSIG 0 345 MPA cut tubing assembly and install Water Regulator K...

Page 6: ...Carbonated Water Setup 1 Purge water to fill carbonator tank by opening carbonator relief valve Close relief valve once water comes out A Relief Valve Open B CO2 Inlet C CO2 Line A B C 2 Activate each...

Page 7: ...he water level Use a screwdriver to adjust if needed A B A Plain Water ON B Syrup Closed 9 Repeat process for each valve 10 Re install the merchandiser splash plate cup rest and drip tray then reattac...

Page 8: ...110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can ca...

Page 9: ...reates a health hazard CAUTION Cleaning and Sanitizing Nozzles 1 Disconnect power so as to not activate valve while cleaning 2 Remove nozzle by twisting counter clockwise and pulling down 3 Remove dif...

Page 10: ...10 WIRING DIAGRAM 115 V 60 Hz R744 WIRING DIAGRAM 230 V 50 Hz 220 V 60 Hz R744...

Page 11: ...M 115 V 60 Hz 230 V 50 Hz 220 V 60 Hz R134A PLUMBING DIAGRAM PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S1 PW1 S2 S3 S4 S5 S6 PLAIN WATER INLET TO CARBONATOR PLUMBING DIAGRAM CE...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: