B. Disconnect check valves (feed line) from top of concentrate containers, and remove concentrate
containers from unit.
C. Remove yellow plug from agitator deck.
D. Using a funnel or tube, fill with water until water flows out of overflow hole into concentrate
container compartment. The overflow water will drain into the drip tray.
NOTE
Facing the front of the unit, the overflow hole is in the rear wall of the concentrate container
compartment.
E. Replace yellow plug.
1.6
CONNECTING TO ELECTRICAL POWER
WARNING
THIS UNIT MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID POSSIBLE FATAL
ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS
PROVIDED WITH A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED
ELECTRICAL OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD TO GROUND THE
UNIT.
DO NOT USE EXTENSION CORDS WITH THIS UNIT. DO NOT “GANG” TOGETHER WITH
OTHER ELECTRICAL DEVICES ON THE SAME OUTLET.
Plug unit power cord into electrical outlet. Compressor and condenser fan motor will not begin
running until five (5) minutes after the unit is energized. Agitator motor will run continuously.
1.7
PURGING UNIT OF AIR
A. Raise front cover and turn key switch ON.
B. Using a cup, actuate each dispensing paddle until a steady flow of water is obtained.
C. Turn key switch OFF.
1.8
LOAD MINUTE PAKS
®
A. Remove lid over concentrate compartment.
B. Minute Paks
®
must be completely thawed and thoroughly shaken before loading.
C. Load each Minute Pak
®
per the flavor label on the front of the unit.
D. Replace check valves (white elbow) in Minute Paks
®
, using a rotating movement while pushing
down.
E. Replace lid on top of unit.
1.9
PRIMING CONCENTRATE PUMPS
A. Turn key switch ON.
B. Depress the Sold Out Reset button.
NOTE
An initial eight (8) to ten (10) ounces (236.6 ml to 295.7 ml) of water will be dispensed before
the concentrate/water mixture reaches the spout.
C. Hold cup under spout and depress the dispensing paddle.
1.10 ADJUST CONCENTRATE TO WATER RATIO (
o
BRIX)
A. Install dispensing nozzles.
B. Inlet water is distributed to two (2) water regulators which supply water to the mixing spouts,
independently of each other. They are marked LEFT and RIGHT, indicating the mixing spout
they supply. On the ESCORT III, the LEFT also supplies the middle spout. Both regulators are
preset at 25 PSIG (1.76 kg/cm
2
). With a proper water source, each spout will dispense
approximately 1.25 ounces of water per second (36 ml/sec). When mixed with concentrate
(5 to 1 ratio), the finished drink will be dispensed at 1.5 ounces per second (43 ml/sec).
C.
There are
NO
select options on ESCORT III units.
These units are factory preset
(electronically) for the spouts and ratios provided in Table 1 (see following page).
2