S8E V3 Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 19 of 27
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000021
Images are for illustration purposes only as product may vary.
No 043-3 – 19 December 2019
Carbonator empty - faulty
Carbonator probe or control.
Low water supply pressure.
Excessive CO
2
Pressure.
Check carbonator control
Using procedure on page 21.
Replace control or probe if defective.
A minimum of 172 kpa water supply
pressure is required
Check function & setting of CO
2
regulator.
Faucet delivers CO2
gas continuously.
Carbonator pump will not run due to
power failure or low voltage.
Pump water supply restricted.
Carbonator pump will not run due to
excessive carbonator CO
2
pressure.
Faulty low pressure switch.
Defective Carbonator motor.
Locked up pump. Motor has cut out
on overload.
Carbonator empty – faulty control
board or level probe.
Carb pump hi temp LED on icebank
control board illuminated.
Check fuses. Check power supply.
Ensure clean mains water supply tap is
open or replace filters.
Check Carbonator CO
2
pressure
regulator for creeping. It should be set at
550 kpa.
Ensure adequate water supply (minimum
pressure 172 kpa flowing pressure).
Pressure switch is set to open below 35
kpa and reset at 172 kpa.
Check operation by plugging into
circulation pump socket momentarily.
Replace motor if necessary.
Replace pump.
Check carbonator control using
procedure on page 21.
Replace control or probe if defective.
Check for icebank growth into product
coils, defrost and turn off chiller at supply
socket and turn on again to reset.