S8E V3 Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 27 of 27
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000021
Images are for illustration purposes only as product may vary.
No 043-3 – 19 December 2019
13. Manufacturer’s Checklist
Checked by ...................................................................... Date .............................................................
Postmix Tested by ........................................................................................................................................
Gas Charge .................................................. Icebank Probe fitted ........................................................
Electrically tested by (P/MIX)
(REF) Refrigeration tested by
..................................................
TAG No. (P/MIX) ........................................................... (REF) .............................................................
High temperature probe located on liquid line between coil and receiver / dryer
Compressor wiring connections label affixed, wiring checked and label signed
Refrigeration system final check. Ensure evaporator fully frosts.
Check all tube work for rubbing e.g. discharge line, liquid line, TX capillary.
Condenser not touching divider panel or grille.
Condenser fans operating and not contacting shroud
Agitator blades tight and not touching coils cradle.
Overflow pipe correct height and positioned straight.
All motors and pumps secured and mounted correctly in correct locations.
All pumps run quietly and carbonator pump switched ON/OFF.
Check icebank probe position and tightness and correct wiring of harness.
Carbonator and plumbing pressure tested. Check for leaks on pumps, clamps, welds, strainers, carbonator fittings and all joints.
Check check valve and strainer indicator correct flow direction
Check correct flow direction
Coils in cradle correctly and spaced.
Postmix tubes not rubbing.
Plumbing strapped correctly and not touching the agitator.
Tube labels on correct tube.
Electrical box labels correctly positioned and Superchiller sticker correctly positioned and straight.
Attention sticker fitted and correctly positioned.
Clean exterior of unit including power cords.
Condenser filter fitted.
Warning sticker applied
Verify L.P. control operation
Spreader pin pointing towards tank.
Check body for sharp edges.
Check lid for cleanliness and rough edges. Fit and secure.
Carbonator relief valve fitted and correct.
Copy checklist & file, put manual/checklist and pump insulator kit in plastic bag & place in the tank area.
Customer asset No.
W/O ...................................................................
Affix label here