17
TROUBLE
CAUSE
REMEDY
4.4 Insufficient water flow.
A. Insufficient incoming supply water
pressure.
B. Shutoff on mounting bloack not fully
open.
C. Foreign debris in water flow control.
D. Foreign debris in water pump strainer
A. Verify incoming supply water pressure
is a minimum of 25 PSI (0.172 MPA).
B. Open shutoff fully.
C. Remove water flow control from upper
body and clean out any foreign material
to ensure smooth free spool movement.
D. Remove water pump strainer and
clean.
4.5 Insufficient syrup flow.
A. Insufficent CO
2
pressure to BIB pumps.
B. Out of CO
2
.
C. Shutoff on mounting block not fully
open.
D. Foreign debris in syrup flow control.
E. Bad syrup pump.
A. Adjust CO
2
pressure to 80 PSI (0.550
MPA) [minimum 70 PSI (0.480 MPA)] for
BIB pumps.
B. Replace CO
2
tank/refill.
C. Open shutoff fully.
D. Remove syrup flow control form upper
body and clean out any foreign material
to ensure smooth free spool movement.
E. Replace BIB pump.
4.6 Erratic ratio.
A. Incoming water and/or syrup supply
not at minimum flowing pressure.
B. Foreign debris in water and/or syrup
flow controls.
A. Check pressure and adjust
B. Remove flow controls from upper body
and clean out any foreign material to
ensure smooth free spool movement.
4.7 No product dispensed
A. Water and syrup shutoffs on mounting
block not fully open.
B. The key switch on an electric valve is
in the OFF position.
C. Cup lever arm or ID panel actuator on
electric valve is not actuating the switch.
D. Electric current not reaching valve.
E. Improper or inadequate water or syrup
supply.
F. Transformer Failure
G. Bad valve solenoid(s)
A. Open shutoff fully.
B. Turn key switch to ON position.
C. Repair
D. Check electric current supplied to
valve. If current is adequate, check
solenoid coil and switch, and replace if
necessary.
E. Remove valve from mounting block
and open shutoffs slightly and check
water and syrup flow. If no flow, check
dispenser for freeze-up or other problems
F. Reset transformer circuit breaker. If
breaker trips again check for pinched wire
harness at backblocks
G. Replace Solenoid(s)
CONTINUED ON NEXT PAGE.....