13
7. Using the keypad, enter a specific volume to be dispensed
based on the size of the graduated cylinder being used to
calibrate the plain water module.
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
10. Repeat steps 8 and 9 until the designated volume is
achieved.
11. Repeat steps 5 - 10 for the carbonated water module.
The larger the volume dispensed, the more accurate
the results.
NOTE
CALIBRATION & MAINTENANCE
Calibrating Plain/Carbonated Water Modules
1. Access the Service menu (See page 7) and press the
Maintenance
button.
2. Remove the two thumb screws connecting the plastic screen
housing to the unit.
3. While holding the plastic screen housing, tilt the housing
forward until the housing disengages from the unit.
5. Using the keypad, enter a water flow rate value of 1.25 oz/
sec.
6. Set the Timer to the ON position and select ounces (oz) as
the desired unit of measurement.
8. With a graduated cylinder placed in a position below the
nozzle, press the
Start Purge
button. The unit will dispense
the volume designated in the previous step.
9. Examine the dispensed volume in the graduated cylinder. If
the dispensed volume does not match the value entered on
the screen in step 7, use a screwdriver to adjust the
plain water flow control. (See Plumbing Diagram on page 17
for reference).
A
A. Tilt Screen Housing
A
B
A. Screen Housing
B. Thumb Screw
4. While holding the screen housing, press the
Calibrate
tab on
the far left side of the screen and press the
Calibrate
button
for the plain water module.