14
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
Calibrating Brand Syrup Modules
1. From the Service menu, press the
Maintenance
button.
2. Remove the two thumb screws connecting the plastic screen
housing to the unit (See page 9).
3. While holding the plastic screen housing, tilt the housing
forward until the housing disengages from the unit (See
page 9).
4. While holding the screen housing, press the
Calibrate
tab on
the far left side of the screen and press the
Calibrate
button
for the first brand syrup module.
5. Set the Timer to the ON position and select seconds (s) as
the desired unit of measurement.
7. With the graduated cylinder placed in a position below the
nozzle, press the
Start Dispense
button. The unit will
dispense the designated syrup for 4 seconds.
8. Examine the dispensed volume in the graduated cylinder.
If the dispensed volume does not match the value of 1.00
oz, use a screwdriver to adjust the brand syrup flow control.
(See Plumbing Diagram on page 17 for reference).
The water flow rate should be set from the calibration
of the carbonated/plain water modules in the previous
section and the ratio should be determined from when
the brand was configured. (See page 12, Adding New
Brand/Flavor Module)
NOTE
The finished drink flow rate was set to 1.5 oz/sec, which
makes the finished syrup flow rate 0.25 oz/s. In 4
seconds, the volume of syrup that should be dispensed
is 1.00 oz.
NOTE
12. To re-attach the screen housing, first align the screen
housing with the connection tabs on the unit, then rotate the
housing down until the connection tabs engage.
13. Re-connect the two thumb screws removed in Step 2.
14. Repeat steps 1 -13 for the second screen.
Make sure both of the connection tabs are disengaged
in the open position before attempting to re-connect
the screen housing. Use a screw driver to open the
connection tabs if necessary.
NOTE
A
A
A. Clip in Open Position
Ensure there is ice on the cold plate and the lines are
cold before attempting to set the flow rates on the
valves. The drink temperature should be no higher
than 40°F (4.4°C) when flow rates are set.
NOTE
6. Using the keypad, enter in a time of 4 seconds as the preset