15
9. Repeat steps 7 and 8 until the designated volume of 1.00
ounce is achieved.
10. Repeat steps 4 - 9 for the remaining brand syrup modules.
11. To re-attach the screen housing, first align the screen
housing with the connection tabs on the unit, then rotate the
housing down until the connection tabs engage.
Calibrating Ambient Flavor Modules
1. Access the Service menu (See page 7) and press the
Maintenance
button.
2. Remove the two thumb screws connecting the plastic screen
housing to the unit (See page 9).
3. While holding the plastic screen housing, tilt the housing
forward until the housing disengages from the unit (See
page 9).
4. While holding the screen housing, press the
Calibrate
tab on
the far left side of the screen and press the
Calibrate
button
for any designated flavor module.
8. With the graduated cylinder placed in a position below the
nozzle, press the Start Purge button. The unit will dispense
the volume designated in the previous step.
9. Examine the dispensed volume in the graduated cylinder. If
the dispensed volume does not match the value entered on
the screen in step 7, use a screwdriver to adjust the
carbonated water flow control. (See Plumbing Diagram on
page 17 for reference).
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
10. Repeat steps 8 and 9 if any more bonus flavor flow
adjustment is necessary.
11. Repeat steps 4 - 10 for any remaining bonus flavor module.
12. To re-attach the screen housing, first align the screen
housing with the connection tabs on the unit, then rotate the
housing down until the connection tabs engage.
7. Using the keypad, enter a specific volume to be dispensed
based on the size of the graduated cylinder being used to
calibrate the flavor module.
5. Using the keypad, enter a flow rate value of 0.062 oz/sec.
6. Set the Timer to the ON position and select ounces (oz) as
the desired unit of measurement.
The larger the volume dispensed, the more accurate
the results.
NOTE
12. Re-connect the two thumb screws removed in Step 2.
13. Repeat steps 1 -12 for the second screen.
Make sure both of the connection tabs are disengaged
in the open position before attempting to re-connect
the screen housing. Use a screw driver to open the
connection tabs if necessary.
NOTE
Make sure both of the connection tabs are disengaged
in the open position before attempting to re-connect
the screen housing. Use a screw driver to open the
connection tabs if necessary.
NOTE
13. Re-connect the two thumb screws removed in Step 2.
14. Repeat steps 1 -13 for the second screen.