27
TROUBLE
CAUSE
REMEDY
BIB pump does not
operate when
dispensing valve is
opened.
1. Out of CO
2
, CO
2
not turned on, or low CO
2
pressure.
2. Out of syrup.
3. BIB connector not tight.
4. Kinks in syrup or gas lines.
1. Replace CO
2
supply, turn on CO
2
supply, or
adjust CO
2
pressure to 70-80 psi (0.483-0.552
MPa).
2. Replace syrup supply.
3. Fasten connector tightly.
4. Straighten or replace lines.
BIB pump operating, but
no flow.
1. Leak in syrup inlet or outlet line.
2. Defective BIB pump.
1. Replace line.
2. Replace BIB pump.
BIB pump continues to
operate when bag is
empty.
1. Leak in suction line.
2. Leaking o-ring on pump inlet fitting.
3. Defective syrup BIB pump.
1. Check BIB connector, if still leaking then re-
place line.
2. Replace o-ring
3. Replace defective pump.
BIB pump fails to restart
after bag replacement.
1. BIB connector not on tightly.
2. BIB connector is stopped up.
3. Kinks in syrup line.
1. Tighten BIB connector.
2. Clean out or replace BIB connector.
3. Straighten or replace line.
BIB pump fails to stop
when dispensing valve
is closed.
1. Leak in discharge line or fittings.
2. Empty BIB.
3. Air leak on inlet line or bag connector.
1. Repair or replace discharge line.
2. Replace BIB.
3. Repair or replace.
Remote Syrup Pump Troubleshooting
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was
purchased. Comply with local regulations regarding disposal of the refrigerant and
insulation.
Dispenser Disposal