8
10. Route appropriate tubing from the remote pump deck outlet
to the carbonated water inlet at unit.
11. Install a shut-off valve in the water line feeding the remote
pump deck as well as the water line feeding the plain water
inlet.
12. Route appropriate tubing from the syrup pump location to the
syrup inlets and connect tubing to all syrup inlets.
A
B
A. Oetiker Pliers
B. Tubing
C. Syrup/Water
Inlet
C
See Plumbing Diagrams on the front of the unit or on
page 31 for reference.
NOTE
Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including fittings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
!
CAUTION
15. Route both drain hoses from designated open type drain
to both fittings on Drip Tray and connect hose to fittings. (if
applicable)
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
F
WARNING
14. Route the power supply cord to a grounded electrical outlet
of the proper voltage and amperage rating.
Pouring hot water into drain may cause the Drain Tube
to collapse. Allow only luke warm or cold water to enter
Drain Tube.
Pouring coffee tea and similar substances
into drain may cause the Drain Tube to become clogged
with coffee or tea grounds, or other solid particles.
!
ATTENTION
16. Reattach Drip Tray and Cup Rest to unit. (if applicable)
When installing the drip tray, make sure both of the
cold plate drain hoses are lined up to the openings in
the drip tray. Make sure the end of the hose rests at
least a half of an inch over the edge of the opening to
ensure proper drainage of the cold plate.
NOTE
13. Route appropriate tubing from the CO
2
source location to the
CO
2
inlet on the unit and connect tubing to inlet.
9. Using tubing cutters, cut the water line and install U-fitting
then route appropriate tubing from the U-fitting to the plain
water inlet at the unit.
A
B
C
D
A. CO2 Inlet
B. Drain Outlet
C. Plain Water Out
D. Carb Water Out
A
B
C
D
A. Remote Pump Deck
B. Pump Inlet
C. Pump Outlet
D. Line to Carb Inlet
A
B
C
A. Line to Water Source
B. U-Fitting
C. Line to Remote Pump Deck
D. Line to Plain Water Inlet
D