9
See Plumbing Diagrams on the front of the unit or on
page 31 for reference.
NOTE
1. Connect appropriate tubing to the carbonated water outlet on
the right side of the unit and route to the carbonated water
inlet on the remote dispenser.
Connecting to Remote Dispenser (if necessary)
2. Connect appropriate tubing to the plain water outlet on the
right side of the unit and route to the plain water inlet on the
remote dispenser.
Installing CO
2
Supply
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
-
Thread regulator nut on to tank, then
tighten nut with wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
2. Connect a 3/8” nut, stem and seal to CO
2
regulator outlet.
A. CO
2
Regulator
B. Wrench
C. 3/8” nut, Stem
D. CO
2
Supply
A
B
C
D
3. Route appropriate tubing from the low pressure CO
2
regulator manifold location to the 3/8” nut, stem on the high
pressure CO
2
regulator attached to source and connect
tubing.
A dedicated CO
2
regulator is required to supply the CO
2
inlet at the unit as well as to all syrup pumps.
!
ATTENTION
This unit has the ability to supply a remote dispenser
with chilled water and carbonated water lines. Please
see the manufacturer’s specifications and instructions
for installation of the remote dispenser. The following
are the instructions for plumbing the water lines to the
remote dispenser.
NOTE
Water lines feeding the remote dispenser must be
insulated.
NOTE
A
B
C
D
A. Line to Dispenser
B. Line to Syrup Pumps
C. Line to CO
2
Regulator
D. CO
2
Regulator Manifold
4. Connect tubing routed from the CO
2
inlet at the unit to one of
the low pressure CO
2
regulator manifold outlets.
5. Connect tubing routed from the tee at the syrup pumps to the
second low pressure regulator.
7. Repeat Step 6 for both low pressure CO
2
regulators on the
regulator manifold routed to the unit and the syrup pumps.
DO NOT TURN ON CO
2
SUPPLY AT THIS TIME
!
WARNING
6. Using a wrench, loosen lock nut on the regulator adjustment
screw of the high pressure CO
2
regulator connected to the
source, then using a screwdriver back out lock nut screw all
the way.
A. CO
2
Regulator
B. Screwdriver
C. Regulator Adjustment Screw
A
B
C