5
12. Route appropriate tubing from the syrup pump location to the
syrup inlets and connect tubing to all syrup inlets.
A
B
A. Oetiker Pliers
B. Tubing
C. Syrup/Water
Inlet
C
See Plumbing Diagrams on the front of the unit or on
NOTE
Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including fittings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
!
CAUTION
15. Route both drain hoses from designated open type drain
to both fittings on Drip Tray and connect hose to fittings. (if
applicable)
A
A. Drain Fitting
B. Drain Line
C. Drip Tray
B
C
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
F
WARNING
14. Route the power supply cord to a grounded electrical outlet
of the proper voltage and amperage rating.
Pouring hot water into drain may cause the Drain Tube
to collapse. Allow only luke warm or cold water to enter
Drain Tube.
Pouring coffee tea and similar substances
into drain may cause the Drain Tube to become
clogged with coffee or tea grounds, or other solid
particles.
!
ATTENTION
16. Reattach Drip Tray and Cup Rest to unit. (if applicable)
When installing the drip tray, make sure both of the
cold plate drain hoses are lined up to the openings in
the drip tray. Make sure the end of the hose rests at
least a half of an inch over the edge of the opening to
ensure proper drainage of the cold plate.
NOTE
13. Route appropriate tubing from the CO
2
source location to the
CO
2
inlet on the unit and connect tubing to inlet.
Connecting to Remote Dispenser (if necessary)
1. Connect appropriate tubing to the carbonated water outlet on
the right side of the unit and route to the carbonated water
inlet on the remote dispenser.
This unit has the ability to supply a remote dispenser
with chilled water and carbonated water lines. Please
see the manufacturer’s specifications and instructions
for installation of the remote dispenser. The following
are the instructions for plumbing the water lines to the
remote dispenser.
NOTE
A
B
C
D
A. CO2 Inlet
B. Drain Outlet
C. Plain Water Out
D. Carb Water Out
See Plumbing Diagrams on the front of the unit or on
page 17 for reference.
NOTE
Water lines feeding the remote dispenser must be
insulated.
NOTE
2. Connect appropriate tubing to the plain water outlet on the
right side of the unit and route to the plain water inlet on the
remote dispenser.