Dispenser Setup

1.  Turn on water source.
2.  Open the pressure relief valve located on the front of the 

unit, by flipping up on the valve cap lever. Hold open until 

water flows from the relief valve then close (flip down) the 

relief valve.

 

The dispenser must be properly electrically grounded 

to avoid serious injury or fatal electrical shock. The 

power cord has a three-prong grounded plug. If a  

three-hole grounded electrical outlet is not available, 

use an approved method to ground the unit. Follow 

all local electrical codes when making connections. 

Each dispenser must have a separate electrical circuit. 

Do not use extension cords. Do not connect multiple   

electrical devices on the same outlet.

WARNING

3. 

Verify all Bag-In-Box contains syrup and check all 

 

connections for leaks.

4. 

Place enough ice in the ice bin to fill approximately 1/2 of the 

bin before plugging in the unit.

5.  Connect unit power cord to grounded electrical outlet. 

7.  Test the motor operation by pushing both ice chute levers 

until agitator motor begins to turn. 

8.  If necessary, turn on the left and right screen by pressing 

the screen on/off toggle buttons on the left side of the unit 

electrical box.

  

The manager’s access to the service menu allows 

 

access to the Lighting screen (see page 12), the Sold 

Out screen (See page 13), and the Time & Delays 

screen (See page 12).

NOTE

14. 

For access to only the Sold Out Menu, repeat steps 10 - 11 

and enter the Sold Out pin 

(963.)

.

15.  From the service menu press the 

Maintenance

 button.

11. 

After you have held your finger for a minimum of four (4) 

 

seconds, tap all four corners of the screen in any order.

12.  A keypad will appear, enter the designated pin number to 

access the service menu. 

13. 

For manager’s access to the service menu, repeat steps 10 - 

11 and enter the manager’s pin number 

(6655)

.

6. 

Turn on the power to the dispenser by pressing the on/off 

toggle button on the right side of the unit electrical box.

9.  Once the screen has booted up, access the service menu by 

placing your finger at the right side edge of the screen. 

10. 

In one swift, fluid motion slide your finger along the center 

of the screen to the left till you reach the left edge of the 

screen, then hold your finger to the screen for a minimum of 

four (4) seconds. 

C

A

B

D

A. Pressure Relief 

    Valve

B. CO2 Inlet

C. Plain Water Out

D. Carb Water Out

A

A. Dispenser Power  

    On/Off

Summary of Contents for Twin Pour

Page 1: ...ss or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Conta...

Page 2: ...ing 585 lbs 265 kg Operating w Ice 745 lbs 338 kg Ice Capacity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch b...

Page 3: ...re that the dispenser is level front to back and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the re...

Page 4: ...n a counterclockwise direction up to a 45 angle 4 Carefully pull ADA panel and electric wire harness from the unit s splash plate until the harness connector is visible 5 Disconnect ADA harness and re...

Page 5: ...Tube to become clogged with coffee or tea grounds or other solid particles ATTENTION 16 Reattach Drip Tray and Cup Rest to unit if applicable When installing the drip tray make sure both of the cold p...

Page 6: ...nut on the regulator adjustment screw of the high pressure CO2 regulator connected to the source then using a screwdriver back out lock nut screw all the way DO NOT TURN ON CO2 SUPPLY AT THIS TIME WA...

Page 7: ...d right screen by pressing the screen on off toggle buttons on the left side of the unit electrical box The manager s access to the service menu allows access to the Lighting screen see page 12 the So...

Page 8: ...flipping the switch on the control box NOTE To check for CO2 leaks close the valve on the CO2 cylinder and observe if the pressure to the system drops with the cylinder valve closed for five minutes O...

Page 9: ...Repeat Steps 4 and 5 for any of the other brand or flavor modules 8 Press the Menu button to return to the Service menu 12 Press the Menu button to return to the Service Menu 13 Repeat steps 1 12 for...

Page 10: ...m on page 17 for reference 1 From the Service menu press the Maintenance button 2 Remove the two thumb screws connecting the plastic screen housing to the unit See page 9 3 While holding the plastic s...

Page 11: ...9 for the remaining brand syrup modules 11 To re attach the screen housing first align the screen housing with the connection tabs on the unit then rotate the housing down untill the connection tabs...

Page 12: ...sing down untill the connection tabs engage 13 Re connect the two thumb screws removed in Step 2 14 Repeat steps 1 13 for the second screen Make sure both of the connection tabs are disengaged in the...

Page 13: ...problem with the specified brand and will dispense when activated Auto signifies that the configured Sold Out Sensor controls whether the brand can be dispensed This feature requires an optional sold...

Page 14: ...ble water at a temperature of 90 F to 110 F Extended lengths of product lines may require additional cleaning solution Sanitizing Solution Prepare the sanitizing solution in accordance with the manufa...

Page 15: ...twenty 20 seconds ensuring all surfaces of the nozzle have been thoroughly rinsed 9 Allow outer nozzle to air dry to expedite drying forced convection is recommended 10 Reinstall the outer nozzle to t...

Page 16: ...ll interior surfaces of the ice chute and the ice chute feed through 29 Wearing sanitary gloves reassemble all removable parts Ensure agitator clip is locked 30 Fill unit with ice and replace Top Cove...

Page 17: ...ement Residual sanitizing solution left in the system creates a health hazard CAUTION 7 Flush out cleaning solution from the flavor injector lines using clean warm water 8 Prepare Sanitizing Solution...

Page 18: ...ED 3 5a C B 3 5a C B 7A C B CONTROL PCB R CONTROL PCB L ICE SOLE ICE SOLE TRIGGER TRIGGER 12VDC 12VDC 24VDC 24VDC 24VDC 115VAC 24VDC 24VDC HDMI HDMI USB USB USB USB CTRL PCB CTRL PCB LEFT SIDE VALVES...

Page 19: ...Blk Red WHT N N N L N G V V V V GRN WHT BLK WHT BLK GRN GRN BLK WHT RED BLK RED WHT BLK WHT BLK BLK WHT WHT BLK BLK RED RED BLK GRN WHT BLK POWER SUPPLY AND IBD CONTROLLER BOX 2 to 1 adapter RIGHT RI...

Page 20: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Reviews: