Page 13
Instrument panel
16 "Cable pressure" manometer [11.2]
displays the pressure of the air that flows to the outlet.
17 "High pressure" manometer [11.1]
displays the pressure in the air storage tank [9.1].
18 ACS addressable compressor monitoring unit
captures 10 physical parameters of the pressurisation
equipment and triggers an alarm when indicated:
• contact,
• system voltage,
• compressor runtime and operating hours,
• relative humidity of output air,
• temperature of output air,
• ambient temperature (option),
• compressor temperature,
• compressor pressure and
• amount of compressed air flow.
19 LED operating voltage
(AC, illuminates if 230 V mains is on).
20 LED Fault
(illuminates if the unit has a fault)