Troubleshooting!
If the compressor does not run, this may be due to an electrical fault or hose lines and air dryer
becoming damp after long idle period.
• The green LED „
F-on
“ (
52
) illuminates in the MFR (
45
) = humidity monitoring is active.
• The red Signal-LED „
F
“ (
48
)
flashes
in the MFR = either the electrical connection to the humidity sensor or
the humidity sensor (
41
) itself is broken.
In this case check the connection-line or change the humidity sensor (
41
) (see page 42 „Causes and remedy
of faults”).
or
• The red Signal-LED „
F
“ (
48
)
illuminates
permanently in the MFR = pressurised air humidity is unadmissibly
high.
In this case leave the equipment to "run dry": see page 43