Emergency mode
If, during maintenance or repair works, the connected pressurised air consumer must continue to be supplied
with pressurised air, a mobile pressurisation equipment (e.g. series LAM) can be connected to the pressurised
air consumers.
Deadly risk!
Switch off operating voltage!
Risk of injury!
Prior to operation, depressurise the equipment by
opening the safety valve "high pressure" (29)!
• Switch off operating voltage or pull out the mains plug!
• Close
shut-off valve (6)
.
• Depressurise the equipment by opening the safety valve
"high pressure" (
29
).
• Remove the pressure hose of the compressed air con-
sumers from equipment output (
12
) at the equipments
back side.
• Attach pressure hose of the compressed air consumers to
the equipment output of the mobile system.
29
• Set mobile system into operation while observing the
respective instruction manual and safety instructions.
12
13
Shut down operation
• Turn off motor protective switch (
43
).
• Plug out power connection cable
• Depressurise equipment!
- Open
shut-off valve (6)
.
• Remove connecting hoses from the equipment output (
12
).
• De-connect monitoring lines (
13
).
• If necessary, branch off electrical connections.
43