9.801-316.0 • Landa ECOS 7000 Operator Manual • Rev. 12/12
OPERA
TOR’S MANU
AL
ECOS 7000
18
With all tanks full, you
have the option of drawing
water from the two outer
tanks, the two inner tanks
or all four tanks.
OPTION 1: To draw water
from the outer tanks set
the outer tank valve to the
"ON" position and the in-
ner tank valve to the "Off"
position. Set the bypass
valve to the outer tank
position.
OPTION 2: To draw water
from the inner tanks set
the outer tank valve to
the "OFF" position and
the inner tank valve to
the "ON" position. Set the
Bypass valve to the inner
tank position.
OPTION 3: To draw wa-
ter from all the tanks set
the outer and inner tank
valves to the "ON" posi-
tion. The bypass valve can
be in the inner or outer
tank position
.
VALVE OPERATION
ON
OFF
ON
OFF
INNER VALVE
OUTER VALVE
BYPASS
VALVE
FROM INNER
TANKS
FROM OUTER TANKS
TO 12V
FEED PUMP
FROM UNLOADER
(BYPASS OUTLET)
TO
INNER
TANKS
TO
OUTER
TANKS
98013160-25