background image

Alle Angaben verstehen sich als unverbindliche Richtwerte! Für nicht schriftlich bestätigte Datenauswahl übernehmen wir keine Haftung. Druckangaben beziehen sich, soweit nicht anders angegeben, auf Flüssigkeiten der Gruppe II bei +20°C.

3

Dokumentation                                     

VORTEX-Rohre

     MAIL:

verkauf@landefeld.de   ·   

TEL:

(05 61) 9 58 85 - 9   ·   

FAX:

(05 61) 9 58 85 - 20

7. Teileliste

8. Abmessungen

3

10

11

9

1

4

6

5

8

2

2

3

4

5

6

7

8

9

10

11

Wirbelka

mm

er

Dichtu

ng

Nadelve

n

til             

Hülse

Ge

n

erator

O-Ri

ng

 17 x 3

O-Ri

ng

 3-8 x 1,4

Verschlusskappe

Ko

n

ter

m

utter

 Re

g

elu

ng

sschraube

 M 4 x 12 Made

n

schraube

1

1/4" BSP Lufta

n

schluss

1/4" BSP 

Luftaus

g

a

ng

212,35

51,65

   Ø 44,50

8.1 VORTEX 14 B

Aus

g

a

ng

 

kalte Luft 

Aus

g

a

ng

 war

m

e Luft

Flexible Verbi

n

du

ng

 

Ma

gn

etische Halteru

ng

1/2" ru

n

de Düse

266,7

Ø 44,50 

mm

67,00

Ø 12,00

1/4" BSP  Lufta

n

schluss

22,22

156,85

101,35

Aus

g

a

ng

 kalte Luft

224.09

48

Lufta

n

schluss

Aus

g

a

ng

 war

m

e Luft

12,60

74,53

8.3 VORTEX 14 CC

8.2 VORTEX 14 KP

Summary of Contents for VORTEX 14 KP

Page 1: ...Stand 08 2018 Dokumentation Vortex Rohre druckluftbetriebene K ltegeneratoren Typ VORTEX 14...

Page 2: ...anderen Seite des Rohres aus Durch ein Regulierventil l sst sich die Temperaturdifferenz zwischen eintretender Druckluft und austretender Kaltluft einstellen Bei sinkender Austrittstemperatur verringe...

Page 3: ...hte Temperatur stellt man mithilfe eines Thermometers ein den man in den kalten Luftstrom h lt und mit dem Regulierventil am Hei luftaustritt die gew nschte Temperatur stufenlos reguliert Durch einfac...

Page 4: ...10 11 9 1 4 6 5 8 2 2 3 4 5 6 7 8 9 10 11 Wirbelkammer Dichtung Nadelventil H lse Generator O Ring 17 x 3 O Ring 3 8 x 1 4 Verschlusskappe Kontermutter Regelungsschraube M 4 x 12 Madenschraube 1 1 4 B...

Page 5: ...pressed air temperature must not exceed 55 C 9 1 Safety and Inspection The VORTEX 14 KP has no moving parts making them virtually maintenance free Clean and dry compressed air moving through the VORTE...

Page 6: ...essure and volume are present to efficiently operate the VORTEX 14 KP a line size of 3 8 pipe or hose should be used for applications 10ft from the main header Use pipe or hose up to 20ft For pipe siz...

Page 7: ...the VORTEX 14 KP The Cold Fraction is adjusted in two ways by adjusting the control relief valve to exhaust more or less air Adjustable version only or by changing the generator inside the VORTEX 14...

Page 8: ...o 70 cold fraction To reset to the factory setting turn the control knob clockwise until closed Once it is completely closed you can set to 70 Cold Fraction by turning the knob 2 5 turns anti clockwis...

Page 9: ...air bled from the line Keep air hoses off the floor where they become tripping hazards and are subject to damage by vehicles doors and dropped tools If possible suspend air hoses from overhead Please...

Page 10: ...lation or replacement cost it s wise to select pipe of an adequate size If there is any doubt that a pipe size may create a pressure drop use the next lar gest size Remember that an oversize pipe comp...

Page 11: ...2 2 1 1 2 2 200 1 1 2 1 1 2 1 1 2 2 2 2 1 1 2 2 225 1 1 2 1 1 2 1 1 2 2 2 2 2 1 1 2 250 2 2 2 2 2 2 2 2 275 2 2 2 2 2 2 2 1 2 2 1 2 300 2 2 2 2 2 2 2 1 2 2 1 2 350 2 2 2 2 2 1 2 2 1 2 2 1 2 2 1 2 400...

Page 12: ...ion on all generators and sizing can be found in section 10 6 D Fit VORTEX 14 CC in place From outside the enclosure place the cold end of the VORTEX 14 CC into the drilled hole E Re fit bulk head nut...

Page 13: ...91 l min Cooling capacity of 703W 2 400 Btu hr A single VORTEX 14 CC is capable of cooling up to 703 Watts 2 400 Btu hr Optimising the cooling capacity is still a vitally important factor choosing the...

Page 14: ...o adjust the set point of the thermostat between 10 and 50 The Set Point is the temperature that once activated the system will cool the cabinet panel to factory set to 22 C 3 Once you have entered yo...

Reviews: