Resolution of the display
15/21
Note:
Central European Time (CET) applies as the standard time.
During daylight saving time the storage takes place at the corre-
sponding times.
7
Resolution of the display
kWh
without decimal place
MWh
3 decimal places
MJ
without decimal place
GJ
3 decimal places
m³/h
0.001
m³
0.01
8
Power supply
The meter can be supplied with power by a battery or by a power supply mod-
ules as preferred.
Options:
6 years battery
11 years battery
Power supply 24 V AC / DC
24 V safety extra-low voltage
Voltage
12...36 V AC or 12
…42 V DC
Frequency
50 / 60 Hz or DC
Galvanic isolation
1000 V DC
Power input
max. 0.8 VA
Connection
cable 1.5 m pre-assembled: PVC,
LIYY 2 x 0.25 mm
2
tin-coated, ex-
ternal diameter 3.6 mm)
Connection in combination with M-Bus
or pulse output
cable 1.5 m pre-assembled: PVC,
LIYY 4 x 0.25 mm
2
tin-coated, ex-
ternal diameter 4.2 mm)