Operating elements
14/21
User loop
User loop
Display type
▼
0054567 kWh
Energy quantity
00065.43 m³
Volume
888888 kWh
Segment test
Info
F - - -
In case of error: message with error
code
Info
Service loop
Service loop
Display type
▼
0.534 m³/h
Current flow
22.9 kW
Current power
84 47 °C
Current temperature hot side / cold
side
04.06.11 D
Date
786 Bh
Operating hours
56 Fh
Missing hours
3792701 G
Device number, 7 digit
Info
PulSE
CH
Remote read out mode (optional)
Info
123 A
Primary address for M-Bus option
Info
2345678 K
Property number, 7 digit
Info
18.02.11 F0
Date stamp for F0 early warning
Info
3- 01 FW
Firmware version
Info
31.12.10 V
Storage day previous year
Previous year
0034321 kWh
Energy previous year on set day
Previous year
00923.12 m³
Volumes: previous year on set day
Previous year
12 Fh
Missing hours previous year
Previous year
- -.- -.- - C
Code input for parameterization
01.06.11 M
Storage day month 1-15
Previous month
over 3s button press:
0034321 kWh
Energy previous month on refer-
ence date
Previous month
00923.12 m³
Volume previous month on refer-
ence date
Previous month
12 Fh
Missing hours previous month on
reference date
Previous month
6.2
Previous years values
The meter saves the following values on the yearly set day (parameterizable)
Energy (meter status)
Volume (meter status)
Missing time (meter status)
6.3
Monthly values
The meter stores the following values for 15 months on the monthly set day
Energy (meter status)
Volume (meter status)
Missing time (meter status)
You can also read the monthly values via the optical interface.