Safety information 

 

5/21 

 

Safety information 

 

The meter may only be used in building service engineer-
ing systems and only for the applications described. 

 

The local regulations (installation etc.) must be adhered to. 

 

Adhere to the operating conditions according to the dial 
plate during use. Non-adherence can cause hazards and 
the warranty will expire. 

 

Adhere to the requirements regarding circulating water 
(CEN / TR 16911:2016). 

 

The meter is only suitable for circulating water in heating 
systems. 

 

The meter is not suitable for potable water. 

 

Do not lift the meter by the electronic unit. 

 

Be aware of sharp points on the thread, flange and meas-
uring tube. 

 

Only personnel, trained in the installation and operation of 
meters in heating and cooling systems, may install and 
remove the meter. 

 

Only install or remove the meter when the pipes are de-
pressurized. 

 

After installing the meter, check the leak-tightness of the 
system. 

 

Warranty and calibration validity will lapse if the calibration 
relevant security seal is broken. 

 

Only clean the meter from outside with a soft, lightly wetted 
cloth. Do not use any spirit or cleaning solvent. 

 

As far as disposal is concerned, the meter is a waste elec-
tronic appliance in the sense of European Directive 
2012/19/EU (WEEE) and it must not be disposed of as 
domestic waste. The relevant national, legal regulations 
must be observed as the appliance must be disposed of 
via the channels provided for this purpose. The local and 
currently valid legislation must be observed. 

 

The meter contains lithium batteries. Do not dispose of the 
meter and the batteries with domestic waste. Observe the 
local stipulations and laws on disposal. 

 
 
 
 

Summary of Contents for ULTRACOLD 2WR6 Series

Page 1: ...ULTRAHEAT T350 2WR6 ULTRACOLD T350 2WR6 Technical Description 32 14 101 001 b Date 19 03 2018 Landis Gyr GmbH Ultrasonic heat and cooling meter T350 2WR6 Residential and district heating...

Page 2: ...verall length 110 mm 130 mm 190 mm Suitable for small mounting locations due to compact construction Construction for residential heating for 105 C and for district heating for 130 C 15 monthly values...

Page 3: ...________________________________________ 13 User loop_______________________________________________________________14 Service loop_____________________________________________________________14 6 2 P...

Page 4: ...two temperature sensors and an electronic unit that calculates the energy consumption from the volume and temperature difference The meter combines modern microcomputer technology with innovative ultr...

Page 5: ...and cooling systems may install and remove the meter Only install or remove the meter when the pipes are de pressurized After installing the meter check the leak tightness of the system Warranty and...

Page 6: ...please observe legal regulations in particular those governing the labelling and packaging of hazardous goods Do not open the batteries Do not bring batteries into con tact with water or expose to te...

Page 7: ...als may be different LCD 7 digit Optical interface Standard EN 1434 3 Communication Optional M Bus or pulse output Protocol IEC 870 300 baud in Nb Separability Always detachable cable length 1 m Tempe...

Page 8: ...0 5 1 5 1 5 110 G 3 4 3 15 6 150 3 9 1 2 1 1 5 130 G1 3 15 6 160 3 8 1 2 1 5 1 5 190 G1 3 15 6 160 3 8 1 2 1 5 2 5 130 G1 5 25 10 200 5 6 1 8 1 5 2 5 190 G1 5 25 10 200 5 6 1 8 1 5 Tolerance of press...

Page 9: ...on situations and the following examples of installation Fit the temperature sensors in the same circuit as the meter Seal the temperature sensor and the fittings to protect against manipula tion If y...

Page 10: ...tes for sensor adapter set A mounting set is included for meters with 5 2 45 mm temperature sen sors With this you can fit the temperature sensor directly immersed into an in sert or a ball valve for...

Page 11: ...rob lems with condensation Fit the immersion sleeves so that the temperature sensor is positioned vertically downwards or horizontally Note Always install the volume measurement unit on the hot side F...

Page 12: ...Dimension of electronic unit 12 21 5 Dimension of electronic unit Fig 10 Dimensions of electronic unit Fig 11 Wall adapter view from above and side...

Page 13: ...ical interface Allows data communi cation with a computer with the necessary service software 3 Calibration rele vant security seal 6 1 Displaying current meter status The meter displays the current m...

Page 14: ...r 0034321 kWh Energy previous year on set day Previous year 00923 12 m Volumes previous year on set day Previous year 12 Fh Missing hours previous year Previous year C Code input for parameterization...

Page 15: ...eter can be supplied with power by a battery or by a power supply mod ules as preferred Options 6 years battery 11 years battery Power supply 24 V AC DC 24 V safety extra low voltage Voltage 12 36 V A...

Page 16: ...e 1 5 m pre assembled PVC LIYY 2 x 0 25 mm2 tin coated ex ternal diameter 3 6 mm Note When reading via M Bus the permissible average reading frequency must not be exceeded 1 every 3 h at 2400 baud 1 e...

Page 17: ...elivery condition F1 Interruption in the hot side temperature sensor Exchange the meter F2 Interruption in the cold side temperature sensor Exchange the meter F3 Electronics for temperature evaluation...

Page 18: ...als K Communication Code Without communication interface 0 With pulse output 1 With M Bus 5 Manufacturer s label Code Logo Landis Gyr 00 Other labels on request xx County where used Code Dial plate fo...

Page 19: ...East English P4C 14 digit is Z Dial plate for Australia English P5C 14 digit is Z Dial plate for Moldavia Romanian P6C 14 digit is Z Dial plate for Spain Spanish P7C 14 digit is Z Dial plate for Serbi...

Page 20: ...1 5 110 G 3 4 150 3 9 C 2 5 190 G1 210 5 3 D 2 5 130 G1 200 5 6 E The indicated pressure loss of a flow sensor is at nominal flowrate qp With the Kv Factor which defines the flow rate at a pressure l...

Page 21: ...21 21 Landis Gyr GmbH Humboldtstrasse 64 90459 Nuremberg Germany...

Reviews: