NEVER CONNECT AN UNREGULATED GAS LINE DIRECTLY TO THE APPLIANCE. A PRESSURE
REGULATOR MUST BE INSTALLED ON ALL GAS EQUIPMENT.
THIS IS REQUIRED BY ALL
LOCAL CODES AND THE CORRECT REGULATOR IS SUPPLIED WITH YOUR APPLIANCE.
The
appliance
is factory set to use either
propane (LP) or natural gas (NAT). It is critical
that the gas you use matches that which the
appliance
was set up for. You can verify that by
checking the
rating plate.
Ensure that the gas supplied meets with the
minimum pressure requirements. Do not operate
the
appliance
on any gas other than that for
which the
appliance
has been set.
Fuel
WC Max Inlet
WC Min Under
Full Load
Nat Gas
7 in
4 in
LP
14 in
11 in
Water Column Requirements
Canadian installations must conform to CGA-
B149.1/.2 natural gas/propane installation
code. (Canada)
LANDMANN recommends that only qualified
professionals perform the required plumbing on
this product.
To ensure satisfactory performance, the gas
supply line must be sized to accommodate the
total BTU requirements of all the gas-fired
equipment that will be connected to that line.
In no case should pipe less than 3/4” inside
diameter or 1” outside diameter ever be used to
connect this product.
• Calculate the total BTU output of all equipmen
t.
Failure to meet these minimum requirements
may reduce performance of the grill and any
other appliances running on that supply line.
Gas Connections
WARNING
Both the regulator and the manifold orifices
have been tuned for the type of gas specified on
the rating plate.
Converting to a different gas type requires the
use of the conversion kit included with this
appliance which must be installed by a qualified
technician
All installation and all installation parts must
conform to local codes with the National Electrical
Code, ANSI Z223.1/NFPA 70 latest edition and
the National Fuel Gas Code, ANSI Z223.1/NFPA
54 in the U.S. and CGA-B149.1/.2 in Canada.
INSTALLATION
:
We do recommend the use of professional help during the installation of your unit as improper
installation may affect your warranty.
9
The Rating plate lists serial numbers, model
numbers and gas
type, it is located underneath
the control panel