background image

INSTALLATION PROCEDURE FOR PATH LIGHT:

1. Prepare footing as required by local codes, see Figs. 1, 2, 5 for recommendations. Run line-in voltage wires up 

through conduit with at least 12” excess wires.

2. Set wooden anchor template in position over conduit. ‘FRONT’ on the template indicates the Front of the unit.

3. Mark anchor hole locations, move the template.

4. Drill holes according to Fig. 2. Clear holes of debris.

5. Assemble the template, concrete anchor, washer and hex bolt as shown in Fig. 3.

6. Test fit anchors into holes. Make any adjustments to the holes as necessary to allow anchors to freely install. 

Anchors should sit centered in hole and not rest against the sides or bottom of the drilled holes.

7. Fill holes with epoxy per epoxy manufacturer’s recommendations.

8. Slowly set anchor template assembly into the holes. Wipe away any excess adhesive. Allow epoxy to cure.

9. Remove hex bolts and washers. Remove template. 

10. Set unit in place, ensuring that base is sitting flat on concrete.

11. Install hex bolts and washers.

12. Remove driver plate cover, see Fig. 6.

13. Connect line-in voltage wires to driver wires, see Fig. 6. Recommended waterproof connectors provided by 

others.

14. Replace driver plate cover.

15. Remove top plate from unit body, see Fig. 7. Retain hardware.

16. Ensure two foam blocks are adhered to each concrete side panel. Install concrete side panels, see Fig. 8 and 

Fig. 9.  Set panel up to unit body and slide down so both tabs on panel engage on receivers on unit body. 

Gently pull out at bottom of concrete panel to ensure bottom tab is engaged. Note orientation of notch in 

panel for single path light units.

17. Reinstall top plate, see Fig. 10

PROCEDURE FOR WIRING:

The Typology path light is assembled at the factory.  The light cartridge is mounted into the head of the pole and 

will not need to be removed during installation.  The LED cartridge is wired to the driver (located in the unit body) 

at the factory.    

The following schematic is to be used to connect the unit to line voltage.  It is the responsibility of the installer to 

make sure that all connections are made in accordance with the NEC and local building codes.  Connection 

hardware not included.

WARNING!: 

LED cartridge and driver are not rated for connection or disconnection while energized. Doing so may 

damage LEDs and will void the warranty.  Disconnect incoming power before making or breaking any electrical 

connections.

Installation Guide

Typology

Path Light

www.landscapeforms.com      Ph: 800.521.2546

Page 2 of 3

Date: March 21, 2022

CAUTION! 

Fixtures and wiring must be installed in accordance with local codes and ordinances. 

NOTES:  

Landscape Forms is not responsible for site preparation, footings, or electrical wiring..

Fig. 6 – Access panel removed

LINE IN

WIRES

SCREW

Fig. 7 – Remove top plate

SCREW

TOP

PLATE

Reviews: