99 (101)
ENG
PROBLEM
PROBABLE CAUSE
SOLUTION
Cloudy water
Dirty filter
Clean filter
Incorrect cleaning
Adjust pH value to recommended range
Particles/organic matter in water
Perform disinfectant shock treatment on spa
Water not replaced on time
Run jet pump(s) and clean filter
Empty and refill spa
Add disinfectant
Water has bad odour
Too much organic matter in water
Perform disinfectant shock treatment on spa
Incorrect cleaning
Add disinfectant
Low pH value
Adjust pH value to recommended range
Smell of chlorine
Chlorine levels too high
Perform disinfectant shock treatment on spa
pH value too low
Adjust pH value to recommended range
Musty odour
Bacterial or algal growth
Perform disinfectant shock treatment on spa. If the problem is visible and
does not disappear, empty the spa, clean it and refill it
Build-up of organic matter/layer of
dirt around spa
Build-up of oils and dirt
Wipe the layer of dirt clean using a clean rag if required. Empty the spa.
Use a cleaning tool and detergent to remove the layer of dirt and refill the
spa
Algal growth
High pH value
Perform disinfectant shock treatment on spa and adjust the pH value.
Low disinfectant level
Perform disinfectant shock treatment on spa and adjust the level of disin-
fectant
Eye irritation
Low pH value
Adjust the pH value
Low disinfectant level
Perform disinfectant shock treatment on spa and adjust the level of disin-
fectant
Skin irritation/rash
Unhygienic water
Perform disinfectant shock treatment on spa and adjust the level of disin-
fectant
Free chlorine level in excess of 5 ppm
Reduce the free chlorine level to below 5 ppm before using the spa
Stains
Incorrect alkalinity value and/or pH value too
low, or too much iron or copper in the water
Adjust the pH value and alkalinity. Use a metal inhibitor.
Deposits
High calcium content in the water. pH value
too high
Adjust the pH value. If the deposits have to be removed, empty the spa,
remove the deposits and balance the water
The spa is not working
No power
Check the power source
The RCD has tripped
Reset the RCD. Call for service is required
The heater’s temperature limiter has tripped
Disconnect the power for at least 30 seconds to reset the heater’s temper-
ature limiter.
Check that the filters are fitted if it does not reset. If the problem persists,
call for service.
The spa is not heating up. The jets
and lights are working (the Ready
and Power indicators are flashing)
Built-in pressure guard open
Check the cassette filter. The built-in pressure switch is reset when the
water flow through the heater has been reset. Call for service if the switch
trips frequently.
The thermo switch on the circulation pump
has tripped
Check the cassette filter and pipe installation. Switch off the power to
the spa. Let the circulation pump cool down. The thermo switch on the
circulation pump is reset once the pump has cooled down and the power
has been switched on again. Call for service if the thermo switch on the
circulation pump trips frequently.
Weak or uneven jets
Water level too low
Fill with water
Filters fitted
Clean filter
Air valve closed
Open air valve
Nozzle closed
Open nozzle
The light does not work
The light’s cabling or fitting is wrong
Replace the light fitting
Light broken
Replace the light
Power indicator flashing (spa cannot
be started)
The heater’s overheating protection has
tripped
Disconnect the power for at least 30 seconds to reset the heater’s overheat-
ing protection. Check that the filters are not blocked. Call for service if the
fault persists.
The Ready indicator is flashing
Temperature sensor triggered
Switch off the power for at least 30 seconds if flashing. Call for service if the
flashing persists.