Page A - 24
A
LW 100 Series
Version: 29.03.2016
Ventilation LW 100 E / E1
• Make sure that the compressor always has a sufficient amount of fresh air available for cooling.
• To prevent serious damage, ensure that the cooling air flow can flow freely.
• The necessary cooling air flow can be calculated by using the following formula:
300 x drive power [kW] = required cooling air flow [m³/h]
Example 11kW motor: 300 x 11kW = 3300 m³/h = required cooling air flow.
• The fan capacity for fresh air and warm air must meet at least the required cooling air flow.
The fans must have the same capacity.
Fig. Ventilation through facade
Fig. Ventilation via ventilation stack
I N S T A L L A T I O N
Summary of Contents for LW 100 B
Page 3: ...A Operating Instructions Breathing Air Compressor LW 100 series Version 29 03 2016 ...
Page 14: ...A S A F E T Y P R E C A U T I O N S ...
Page 21: ...A I N S TA L L AT I O N ...
Page 29: ...A O P E R AT I O N ...
Page 37: ...A R E M E D Y I N G FA U LT S ...
Page 42: ...A M A I N T E N A N C E A N D S E R V I C E ...
Page 68: ...A M A I N T E N A N C E R E C O R D S ...
Page 77: ...B ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS ...
Page 118: ...C O P T I O N S Version 11 12 D ...
Page 120: ...C A D D I T I O N A L F I L L I N G H O S E C 2 LW 100 Series ...
Page 122: ...C S W I T C H O V E R D E V I C E 2 0 0 3 0 0 B A R C 4 LW 100 Series ...
Page 126: ...C A U T O M A T I C C O N D E N S AT I O N D R A I N C 8 LW 100 Series ...
Page 130: ...C A U T O S H U T D O W N C 12 LW 100 Series ...
Page 135: ...C S P E C I A L M O T O R S C 17 LW 100 Series ...
Page 144: ...C S P E C I A L V O LTA G E C 26 LW 100 Series ...